Parameter Conditions/Description Min Nom Max Units
Input Voltage Continuous 36 48 75 VDC
Turn-On Input Voltage Ramping Up 32 - 35 VDC
Turn-Off Input Voltage Ramping Down 31 - 33 VDC
Turn-On Time To Output Regulation Band
100% Resistive Load
5 10 ms
Input Reflected Ripple Current Full Load, 12 µH source inductance 80 mA p-p
Inrush Transient Vin = Vin.max 0.1 A
2
s
Output Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Output Voltage Setpoint Accuracy Vin = Vin.nom, Full Load -1 1 %Vout
Output Current * HLS30 3 30 ADC
HLS40 4 40 ADC
Line Regulation Vin.min to Vin.max, Iout.max
HLS30 0.25 %Vout
HLS40 0.5 %Vout
Load Regulation Vin=Vnom, Iout.min to Iout.max
HLS30 0.2 %Vout
HLS40 0.5 %Vout
Output Temperature Regulation
(Tboad temp) =-40°C to +100°C)
- 0.03
%/°C
Remote Sense Headroom Note: *** 10 %Vout
Dynamic Regulation
Peak Deviation
Settling Time
50-75% load step change
to 1% error band
8
500
%Vout
μs
Admissible Load Capacitance Iout.max, Nom Vin 30,000
μF
Output Current Limit Threshold ** Vout≤0.97Vout.nom 110 140 %Iout
Switching Frequency HLS30ZD 210 kHz
HLS30ZG & HLS30ZE 300 kHz
HLS40ZA & HLS40ZB 250 kHz
Overvoltage Protection,
Non Latching (hiccup type)
Over all input voltage and load
conditions
115 140 %Vout
Trim Range Iout.max, Vin = Vnom 90 110 %Vout
* At Iout<Iout.min, the output may contain low frequency component that exceeds ripple specifications.
** Overcurrent protection is non-latching (hiccup type) with auto recovery.
*** Vout can be increased up to 10% via the sense leads or up to 10% via the trim function, however total output voltage trim from all
sources should not exceed 10% of Vout