6
Thermal Derating Curve Figures
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
Description Symbol PDIP Option 060 SO-8 Option 060 Unit
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I – IV
I – IV
I – III
I – IV
I – IV
I – III
Climatic Classication 40/85/21 40/85/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
630 567 Vpeak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
=1 sec,
Partial discharge < 5 pC
V
PR
1181 1063 Vpeak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
=10 sec, Partial
discharge < 5 pC
V
PR
1008 907 Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
= 60 sec)
V
IOTM
6000 6000 Vpeak
Safety-limiting values
– maximum values allowed in the event of a failure.
Case Temperature T
S
175 150 °C
Input Current I
S, INPUT
230 150 mA
Output Power P
S, OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥10
9
≥10
9
W
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
0
0
T
S
– CASE TEMPERATURE – °C
HCPL-060L/HCPL-063L
200
700
400
25
800
50 75 100
200
150 175
P
S
(mW)
I
S
(mA)
125
100
300
600
500
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
0
0
T
S
– CASE TEMPERATURE – °C
200
700
400
25
800
50 75 100
200
150 175
P
S
(mW)
I
S
(mA)
125
100
300
600
500
HCPL-260L/HCPL-263L