2/11
XC74UL4066
PARAMETER SYMBOL RATINGS UNITS
Supply Voltage VCC -0.5~+6.0 V
Control Input Voltage VCONT -0.5~+6.0 V
Switch Output Voltage VOUT -0.5~VCC+0.5 V
Control Input Diode Current IIK -20 mA
Switch Output Diode Current IOK ±20 mA
Switch Output Current IOUT ±25 mA
VCC,GND Current ICC,IGND ±50 mA
SSOT-25 150
Power Dissipation
*
SON-6
Pd
200
mW
Storage Temperature Range Tstg -65~+150 ℃
PARAMETER SYMBOL VCC(V) CONDITIONS UNITS
Supply Voltage VCC - 2~5.5 V
Input Voltage VIN - 0~5.5 V
Output Voltage VOUT - 0~VCC V
Operating Temperature Range Topr - -40~+85 ℃
3.3 0~100
Input Rise and Fall Time tr,tf
5.0 0~20
ns/V
Ta=25℃ Ta=-40 ℃~85℃
PARAMETER SYMBOL
VCC(V)
CONDITIONS
MIN. TYP. MAX. MIN. MAX.
UNITS
2.0 1.5
- -
1.5
-
3.0 2.1
- -
2.1
-
“High” Level Control
Input Voltage”
V
IH
5.5
3.85
- -
3.85
-
V
2.0
- -
0.5
-
0.5
3.0
- -
0.9
-
0.9
“Low” Level Control
Input Voltage”
V
IL
5.5
- -
1.65
-
1.65
V
2.0 VCONT=VIH
-
130 350
-
550
3.0 VIN=0~VCC
-
22 50
-
65
Peak ON Resistance RONmax
4.5 I
IN/OUT=1mA
-
12 25
-
35
2.0 VCONT=VIH 23 50 65
3.0
V
IN=GND or VCC
14 30 40
ON Resistance RON(1)
4.5 I
IN/OUT=1mA 10 20 25
Ω
Power Off Leak Current IS(OFF) 5.5 VCONT=VIL, VIN=VCC, VOUT=GND
- - ±0.1 - ±1.0 μA
Power On Leak Current IS(ON) 5.5 VCONT=VIH, VIN=VCC, OR GND
- - ±0.1 - ±1.0 μA
Control Input Current ICONT 5.5 VIN=VCC or GND
- - ±0.1 - ±1.0 μA
Static Supply Current ICC 5.5 VIN=VCC or GND
- -
1.0
-
5.0
μA
■RECOMMENDED OPERATING CONDITIONS
■DC ELECTRICAL CHARACTERISTICS
■ABSOLUTE MAXIMUM RATINGS
Ta=-40 ℃~85℃
Voltage is all ground standardized.
*Ta=25℃