Si8410/20/21 (5 kV)
Si8422/23 (2.5 & 5 kV)
16 Rev. 1.2
Table 5. Recommended Operating Conditions
Parameter
Symbol Test Condition Min Typ Max Unit
Ambient Operating Temperature* T
A
150 Mbps, 15 pF, 5 V –40 25 125 C°
Supply Voltage V
DD1
2.70 — 5.5 V
V
DD2
2.70 — 5.5 V
*Note: The maximum ambient temperature is dependent upon data frequency, output loading, the number of operating
channels, and supply voltage.
Table 6. Regulatory Information*
CSA
The Si84xx is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
61010-1: Up to 600 V
RMS
reinforced insulation working voltage; up to 600 V
RMS
basic insulation working voltage.
60950-1: Up to 600 V
RMS
reinforced insulation working voltage; up to 1000 V
RMS
basic insulation working volt-
age.
60601-1: Up to 125 V
RMS
reinforced insulation working voltage; up to 380 V
RMS
basic insulation working voltage.
VDE
The Si84xx is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
60747-5-2: Up to 891 V
peak
for basic insulation working voltage.
60950-1: Up to 600 V
RMS
reinforced insulation working voltage; up to 1000 V
RMS
basic insulation working volt-
age.
UL
The Si84xx is certified under UL1577 component recognition program. For more details, see File E257455.
Rated up to 5000 V
RMS
isolation voltage for basic insulation.
*Note: Regulatory Certifications apply to 2.5 kV
RMS
rated devices which are production tested to 3.0 kV
RMS
for 1 sec.
Regulatory Certifications apply to 5.0 kV
RMS
rated devices which are production tested to 6.0 kV
RMS
for 1 sec.
For more information, see "6. Ordering Guide" on page 29.