www.vishay.com For technical questions, contact: optocoupleranswers@vishay.com
Document Number: 81135
544 Rev. 1.0, 04-Mar-10
K827PH, K847PH
Vishay Semiconductors
Optocoupler, Phototransistor Output
Notes
(1)
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not
implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute
maximum ratings for extended periods of the time can adversely affect reliability.
(2)
Refer to wave profile for soldering conditions for through hole devices.
Note
(1)
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
COUPLER
AC isolation test voltage (RMS) t = 1 min V
ISO
5000 V
RMS
Total power dissipation P
tot
250 mW
Operating ambient temperature range T
amb
- 40 to + 100 °C
Storage temperature range T
stg
- 55 to + 125 °C
Soldering temperature
(2)
2 mm from case, t ≤ 10 s T
sld
260 °C
ELECTRICAL CHARACTERISTICS
(1)
(T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
INPUT
Forward voltage I
F
= 50 mA V
F
1.25 1.6 V
Junction capacitance V
R
= 0 V, f = 1 MHz C
j
50 pF
OUTPUT
Collector emitter voltage I
C
= 100 μA V
CEO
70 V
Emitter collector voltage I
E
= 100 μA V
ECO
7V
Collector dark current V
CE
= 20 V, I
F
= 0, E = 0 I
CEO
100 nA
COUPLER
Collector emitter saturation voltage I
F
= 10 mA, I
C
= 1 mA V
CEsat
0.3 V
Cut-off frequency
I
F
= 10 mA, V
CE
= 5 V,
R
L
= 100 Ω
f
c
100 kHz
Coupling capacitance f = 1 MHz C
k
0.3 pF
ABSOLUTE MAXIMUM RATINGS
(1)
(T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL VALUE UNIT
CURRENT TRANSFER RATIO
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
I
C
/I
F
V
CE
= 5 V, I
F
= 5 mA
K827PH CTR 50 600 %
K847PH CTR 50 600 %