Z650-0.32-IS510-U

2201-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
Z+ High Voltage Series
Features
2U high
Built-in USB, RS-232 & RS-485 Interface
Optional LAN, GPIB & Isolated Analog Programming
Bench or Rack Mount
Constant Current or Voltage Modes
Five Year Warranty
200-800W Programmable Power Supplies
Key Market Segments & Applications
Part Number
19” Rack Housing
(Accepts four 105mm width units or six 70mm width units) Z-NL100
Blanking Panel for 19” Rack (70mm) Z-BP
Blanking Panel for 19” Rack (105mm) Z-WBP
Dual/Triple Housing
(Accepts two 105mm case units or three 70mm case units) Z-NL200
Serial Link Cable (One is included with each power supply) Z-RJ45
Communication Cable RS485 Z-485-9
Communication Cable RS232 Z-232-9
North American Line Cord (One included with -U suf x) Z-U
Accessories
Option Code
IEC320 cable USA plug (Included in model number above) -U
Front panel insulated output sockets (650V or 5A max)* -L2
Only one of the options below can be included:
GPIB Interface* -IEEE
Voltage Programming Isolated Analog Interface* -IS510
Current Programming Isolated Analog Interface* -IS420
LAN Interface -LAN
*Requires wide body (105mm) case style
Options
Z160-1.3-LAN-U
Part Number Example
Voltage Current Max Ripple Noise Ripple Ef ciency
Adjust Adjust Power 5Hz-1MHz 20MHz BW 5Hz-1MHz %
Model Range Range (W) (mV) (mV) (mA) (100-200VAC)
Z160-1.3-U 0 - 160 0 - 1.3 208 10 100 1.2 79 / 81
Z160-2.6-U 0 - 160 0 - 2.6 416 10 100 1.5 84 / 86
Z160-4-U 0 - 160 0 - 4 640 10 100 2.0 86.5 / 88.5
Z160-5-U 0 - 160 0 - 5 800 10 100 2.0 86.5 / 88.5
Z320-0.65-U 0 - 320 0 - 0.65 208 25 150 0.8 79 / 81
Z320-1.3-U 0 - 320 0 - 1.3 416 25 150 1.0 84 / 86
Z320-2-U 0 - 320 0 - 2 640 30 150 1.5 87 / 88.5
Z320-2.5-U 0 - 320 0 - 2.5 800 30 150 1.5 86.5 / 89
Z375-2.2-U 0 - 375 0 - 2.2 825 30 150 1.5 87.5 / 89.5
Z650-0.32-U 0 - 650 0 - 0.32 208 60 250 0.5 79 / 81
Z650-0.64-U 0 - 650 0 - 0.64 416 60 250 0.6 84 / 86
Z650-1-U 0 - 650 0 - 1 650 60 250 1.0 86.5 / 88.5
Z650-1.25-U 0 - 650 0 - 1.25 812 60 250 1.0 87 / 89
Model Selector
2211-800-526-2324 • www.us.tdk-lambda.com/lp/
Revision A5: Aug 2016
Z+ Series
Model Z160 Z320 Z375 Z650
Load Regulation CV 0.01% of rated voltage over 0 - 100% load change
Line Regulation CV 0.01% of rated voltage over 0 - 100% input change
Recovery Time (1) CV 2ms
Temperature Coef cient CV 30ppm/°C following 30 minute warm up
Temperature Stability CV 0.02% of rated voltage over 8 hours following 30 minute warm up time
Warm up Drift (2) CV <0.05% of rated voltage of rated output voltage
Up programming response time (10-90% or 90-10% of Vmax) CV 80ms 150ms 55ms 150ms
Down programming resp time (CV) (10-90% or 90-10% of Vmax) Full load 100ms 150ms 65ms 150ms
Down programming resp time (CV) (90-10% of Vmax) Zero load 2ms 2.5ms 2.5ms 3ms
Load Regulation CC 0.09% of rated current over 0 - 100% Vout change
Load Regulation thermal drift CC < 0.05% of rated current over 30 minutes after load change
Line Regulation CC 0.02% of rated current over a 85 - 132 or 170 - 265VAC line change
Temperature Coef cient CC 100ppm/°C of rated current after 30 minute warm up time
Temperature Stability CC 0.05% of rated current over 8 hours following 30 minute warm up time
Warm up Drift(2) CC <±0.1% of rated current
Vout & Iout programming & readback resolution Digitally < 0.012% of rated voltage/current
Vout & Iout programming & readback accuracy Digitally 0.05% of rated voltage + 0.05% of actual, 0.2% of rated current
Voltage & Current Programming Analog By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k)
Voltage & Current Monitoring Analog 0-5V or 0-10V Voltage (user selectable), ±1% accuracy
Overvoltage Shutdown (user programmable) V 5 - 176 5 - 353 5 - 413 5 - 717
Overtemperature Protection - User selectable - latched or non-latching
Display - Voltage - 4 digits. Accuracy 0.5% of rated voltage or current ± 1 count
Remote On/Off - By applied voltage or dry contact relay (user selectable logic)
Output Good - Open Collector, Low on fail
Remote Sense Compensation (per wire) V 5 5 5 5
Communication Interface - RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional
Series Operation - Up to two identical units (with external diodes)
Parallel Operation - Up to six units in master-slave con guration
Input Voltage / Frequency - 85-265VAC, 47-63Hz
Inrush Current - < 25A
Hold Up Time (Typical) ms 16ms
Power Factor Correction - Complies with EN61000-3-2 Class A (0.99 typ)
Operating Temperature °C 0 - 50°C
Storage Temperature °C -20 to +85°C
Humidity (non condensing) %RH Operating: 20 - 90%RH, Storage 10 - 95%RH
Cooling - Internal temperature controlled fan
Withstand Voltage - I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min
Insulation Resistance - >100M at 25°C & 70%RH
Vibration (non operating) - IEC60068-2-64
Shock - <20G, half sine, 11ms. IEC60068-2-27
Safety Agency Certi cations - UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1)
Immunity - IEC61326 (Designed to meet EN55022 / EN55024)
Conducted EMI - IEC/EN61326-1 Industrial location B, FCC part 15-B, VCCI-B
Radiated EMI - IEC/EN61326-1 Industrial location A, FCC part 15-A, VCCI-A
Size (H x W x D) (Excluding handles and busbars) mm Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm
Weight kg Standard body 1.9kg; Wide Body 2.4kg
Warranty yrs Five Years
Speci cations (See brochure on website for full detailed speci cations)
Notes:
(1) Recovery to within 0.5% of rated voltage after a load
change of 10-90% (Output current 10-100% of Imax)
(2) Over 30 minute warm up time after power on
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zplus-series.htm

Z650-0.32-IS510-U

Mfr. #:
Manufacturer:
TDK-Lambda
Description:
PWR SUPPLY OUTPUT 0-650V 0-.32A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union