AEJ11012

2014.02
industrial.panasonic.com/ac/e/ Panasonic Corporation 2014©
Automation Controls Catalog
–1–
ASCTB117E 201402-T
ORDERING INFORMATION
TYPES
Standard packing: Carton: 1 pc.; Case: 20 pcs.
RATING
1. Coil data
High capacity DC cutoff
100A at 100V DC
EJ RELAYS (AEJ)
Contact arrangement Nominal coil voltage Protective construction Terminal shape Part No.
1 Form A
12V DC
Dust cover Screw terminal
AEJ11012
24V DC AEJ11024
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal coil current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
12V DC
75%V or less of
nominal voltage
(Initial)
8.3%V or more of
nominal voltage
(Initial)
417mA 28.8 5.0W
133%V of
nominal voltage
24V DC 208mA 115.2 5.0W
Protective construction: Dust cover type
RoHS compliant
FEATURES
1. Compact and high capacity using
double contacts in series and
permanent magnet installed
1) Nominal switching capacity (resistive
load): 100A 100V DC, Min. 10
4
2) Max. cut-off current: 800A 100V DC
2. Compact and lightweight for space
savings
70mm (L) × 80mm (W) × 34mm (H)
2.756inch (L) × 3.150inch (W) ×
1.339inch (H)
3. Environmentally friendly
In consideration of the environment,
cadmium-free contacts, lead-free solder
are used.
TYPICAL APPLICATIONS
Quick recharging power supplies for
AGVs (automatic guided vehicle), UPS
(uninterruptible power supplies), Fuel
cell, Combined heat/power generation
system, etc.
EJ Relay
Contact arrangement
1: 1 Form A
AEJ
Contact capacity
1: 100 A (100 V)
Nominal coil voltage (DC)
12: 12 V, 24: 24 V
Operating function
0: Single side stable
Panasonic Corporation 2014©
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
EJ (AEJ)
–2–
ASCTB117E 201402-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value.
Refer to Usage, transport and storage conditions in NOTES.
*3. Condition: Nominal switching 100cycles, each cut off 800A
*4. When using a surge absorbing element for the relay coil drive circuit, please use with a surge absorbing element with a clamp voltage of 1.5 to 2.0 times the rated
operating voltage. When the coil is connected in parallel with a diode, resistor or capacitor, the release time will delay which might lead to degradation in shutoff
performance and electrical life.Contact terminals have polarity; therefore, please obey the wiring diagram when connecting contacts.The electrical load
performance value applies when a varistor is connected in parallel with the coil.
REFERENCE DATA
Characteristics Item Specifications
Rating
Arrangement 1 Form A
Contact voltage drop (Initial) Max. 0.15V (at 100A)
Contact material Ag alloy type
Nominal switching capacity (resistive load) 100A 100V DC
Max. carrying current/short time carrying current 1,000A (0.1s)
Min. switching capacity (Reference value)*
1
1A 12V DC
Max. cut-off current 800A 100V DC 3 cycle*
3
Overload opening rating 300A 150V DC 10 cycle
Electrical
characteristics
Insulation resistance (Initial) Min. 100M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,500 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 2,500 Vrms for 1min. (Detection current: 10mA.)
Operate time (at 20°C 68°F) Max. 30ms (Nominal voltage applied to the coil, excluding contact bounce time)
Release time (at 20°C 68°F) Max. 15ms (Nominal voltage applied to the coil)
Mechanical
characteristics
Shock resistance
Functional
Min. 500 m/s
2
(Nominal voltage applied to the coil)
Min. 50 m/s
2
(deenergized) (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive
Min. 1000 m/s
2
(Nominal voltage applied to the coil or deenergized.)
(Half-wave pulse of sine wave: 6 ms)
Vibration resistance
Functional 10 to 200Hz, 44.1m/s
2
(Nominal voltage applied to the coil or deenergized)
Destructive
10 to 200Hz, 44.1m/s
2
(Nominal voltage applied to the coil or deenergized)
(Time of vibration for each direction; X, Y, Z direction: 4 hours)
Expected life
Mechanical Min. 10
6
Electrical
Min. 10
4
(at 100A 100V DC)
(Resistive load, operating frequency 1s ON, 9s OFF, room temperature)
Conditions Conditions for operation, transport and storage*
2
Ambient temperature: –40°C to +85°C –40°F to +185°F
Unit weight Approx. 300g 10.58oz
1. Maximum value for switching capacity 2. Carrying current limit
Connection electric wire: 40mm
2
Ambient temperature: 85°C 185°F
Standard for judgment: Relay contacts off when
carrying finished.
Carrying current and carrying time
1,000
100
10
10 100 1,000
Contact voltage, V
Contact current, A
DC resistive load
0.1
1
10
10000
1000
100
0 200 400 600 800 1000 1200
Carrying current, A
Carrying time, s
3. Distribution of pick-up and drop-out voltages
Tested sample: AEJ11012, 50 pcs.
4. Distribution of operate time
Tested sample: AEJ11012, 50 pcs.
5. Distribution of release time
Tested sample: AEJ11012, 50 pcs.
0
15
10
5
20
25
3.02.01.51.0 2.5 3.5 4.5 5.04.0 5.5 6.0 7.06.5
Pick-up
voltage
Drop-out
voltage
)(20°C 68°F
Voltage, V
Quantity
0
5
10
15
20
13.011.010.0 12.0 14.0 16.0 17.015.0 18.0 19.0 20.0
Time, ms
Quantity
)(20°C 68°F
0
5
10
15
25
20
1.50.50.0 1.0 2.0 3.0 3.52.5 4.0 4.5 5.0
Time, ms
Quantity
)(20°C 68°F
Panasonic Corporation 2014©
Panasonic Corporation Automation Controls Business Division
industrial.panasonic.com/ac/e/
EJ (AEJ)
–3–
ASCTB117E 201402-T
DIMENSIONS (mm inch)
6. Functional shock resistance
Tested sample: AEJ11012, 3 pcs.
Half-wave pulse of sine wave: 11 ms
Detection time: 10µs.
Applied direction: 6 directions
Applied cycle: Each of 3 cycles
Y'
Y
XZ
Z' X'
X'
Z'
Z
X
Y'
Y
Deenengized condition
Energized condition
1,000m/s
2
1,000m/s
2
1,000m/s
2
1,000m/s
2
1,000m/s
2
1,000m/s
2
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
<>
2-M6
300±20
71.4
58.4
36.0
3.7
3.7
(–) (+)
52.0
66.0±0.3
80.0
27.0
70.0
31.5
37.5
15.0
10.0
+1.0
0.5
34.0
+.039
.020
1.339
+1.0
0.5
33.6
+.039
.020
1.323
2-5.3 dia.
2-.209 dia.
+0.3
0.1
+.012
.004
2-M.236
11.811±.787
2.811
2.299
1.417
.146
.146
2.047
2.598±.012
3.150
1.063
2.756
1.240
1.476
.591
.394
Notes: 1. Please be warned that contact terminals have polarity. There is no polarity in the coil input line.
2. Cross-sectional area of coil lead wire: 0.5mm
2
Schematic (Top view)
Mounting hole pattern (Top view)
Tolerance: ±0.1 ±.004
Coil terminal
Coil terminal
2 (–)
1 (+)
66.0
2-5.3
2.598
2-.209
CAD Data
Dimension:
Less than 10mm .394inch:
10 to 50mm .394 to 1.969inch:
Min. 50mm 1.969 inch:
General tolerance
±0.3 ±.012
±0.6 ±.024
±1.0 ±.039

AEJ11012

Mfr. #:
Manufacturer:
Panasonic
Description:
General Purpose Relays H Voltage Relay 12v