G3H-203SN DC5-24

1
CSM_G3H_G3HD_DS_E_6_3
Solid State Relays G3@-VD
G3H/G3HD
New Models with International Standards
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power
Relays
• Certified by UL, CSA, and VDE (models numbers with a suffix
of “-VD”).
• Socket type, same size as LY Power Relays.
• Operation indicator provided to confirm input (models numbers
with “N” before the suffix).
Refer to Safety Precautions for All Solid State
Relays.
Note: The socket is optional.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
1. Basic Model Name
G3H: Solid State Relay
2. Rated Load Power Supply Voltage
2: 200 VAC
3, 4. Rated Load Current
03: 3 A
5. Terminal Type
S: Plug-in terminals
6. Zero Cross Function
Blank: Equipped with zero cross function
L: Not equipped with zero cross function
7. Operation Indicator
Blank: Not equipped with operation indicator
N: Equipped with operation indicator
8. Certification
VD: Certified by UL, CSA, and VDE standards
1. Basic Model Name
G3H: Solid State Relay
2. Load Power Supply Type
D: DC
3. Rated Load Power Supply Voltage
X: 50 VDC
4. Rated Load Current
03: 3 A
5. Terminal Type
S: Plug-in terminals
6. Operation Indicator
Blank: Not equipped with operation indicator
N: Equipped with operation indicator
7. Certification
VD: Certified by UL, CSA, VDE
1
234 56
7
8
G3H-@@@@@@-@
1
23456
7
G3HD-@@@@-@
G3H/G3HD
2
Ordering Information
List of Models
*1 Product is labelled “240 VAC”.
*2 Product is labelled “48 VDC”.
*3 Product is labelled “240 VDC”.
*4 Application is possible for a half-wave rectification load between 19.2 and 264 VAC.
Accessories (Order Separately)
Connecting Sockets/Hold-Down Clips
Specifications
Ratings (at an Ambient Temperature of 25°C)
Input
Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays.
2. With constant current input system.
Isolation Zero cross
function
Indicator Rated output load Rated input voltage Model
Photocoupler Yes Yes 3 A at 100 to 240 VAC *1 5 to 24 VDC G3H-203SN-VD
Phototriac coupler No 5 VDC G3H-203SLN-VD
12 VDC
24 VDC
Photocoupler --- 3 A at 4 to 48 VDC *2 5 to 24 VDC G3HD-X03SN-VD
Photocoupler Yes No 3 A at 100 to 240 VAC *1 4 to 24 VDC G3H-203S-VD
Phototriac coupler No 5 VDC G3H-203SL-VD
12 VDC
24 VDC
Photocoupler --- 3 A at 4 to 48 VDC *2 4 to 24 VDC G3HD-X03S-VD
Photovoltaic coupler --- Yes 2.5 A at 24 to 240 VDC 12 to 24 VDC G3HD-202SN-VD
Front-mounting Sockets Back-mounting Sockets
Socket PTF08A(-E) PT08 PT08-0 PT08QN
Hold-down Clip PYC-A1 PYC-P
PYC-S
PYC-P PYC-P
PYC-S
Model Rated voltage Operating voltage Impedance Voltage level
Must operate voltage Must release voltage
G3H-203SN-VD 5 to 24 VDC 4 to 28 VDC 15 mA max. (See note 2.) 4 VDC max. 1 VDC min.
G3H-203SLN-VD 5 VDC 4 to 6 VDC 390 Ω±20% 4 VDC max. 1 VDC min.
12 VDC 9.6 to 14.4 VDC 900 Ω±20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 2 kΩ±20% 19.2 VDC max.
G3HD-X03SN-VD 5 to 24 VDC 4 to 28 VDC
1.5 kΩ
+20%
/
–10%
(See note 1.)
4 VDC max. 1 VDC min.
G3H-203S-VD 4 to 24 VDC 3 to 28 VDC 15 mA max. (See note 2.) 3 VDC max. 1 VDC min.
G3H-203SL-VD 5 VDC 4 to 6 VDC 390 Ω±20% 4 VDC max. 1 VDC min.
12 VDC 9.6 to 14.4 VDC 900 Ω±20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 2 kΩ±20% 19.2 VDC max.
G3HD-X03S-VD 4 to 24 VDC 3 to 28 VDC
1.5 kΩ
+20%
/
–10%
(See note 1.)
3 VDC max. 1 VDC min.
G3HD-202SN-VD 12 to 24 VDC 9.6 to 28.8 VDC 25 mA max. (at 24 VDC)
(See note 2.)
9.6 VDC max. 1 VDC min.
*3
*4
G3H/G3HD
3
Output
Characteristics
Engineering Data
Model Applicable load
Rated load voltage Load voltage range Load current Inrush current
G3H-203SN-VD
G3H-203S-VD
100 to 240 VAC 75 to 264 VAC 0.1 to 3 A at 40°C 45 A 60 Hz, 1 cycle
G3H-203SLN-VD
G3H-203SL-VD
G3HD-X03SN-VD
G3HD-X03S-VD
4 to 48 VDC 3 to 52.8 VDC 0.1 to 3 A at 40°C 18 A (10 ms)
G3HD-202SN-VD 24 to 240 VDC 19.2 to 264 VDC 0.001 to 2.5 A at 40°C 20 A (10 ms)
Model G3H-203SN-VD/203S-VD G3H-203SLN-VD/203SL-VD G3HD-X03SN-VD/X03S-VD G3HD-202SN-VD
Operate time 1/2 cycle of load power
source + 1 ms max.
1 ms max. 0.5 ms max. 5 ms max.
Release time 1/2 cycle of load power source + 1 ms max. 2 ms max. 10 ms max.
Output ON voltage drop 1.6 V (RMS) max. 3 V max. (output ON-resis-
tance: 1.25 Ω max.)
Leakage current 5 mA max. (at 100 VAC);
10 mA max. (at 200 VAC)
2.5 mA max. (at 100 VAC);
5 mA max. (at 200 VAC)
5 mA max. (at 50 VDC) 0.1 mA max. (at 200 VDC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock resistance
Destruction: 1,000 m/s
2
Ambient temperature Operating: –30°C to 80°C (with no icing)
Storage: –30°C to 100°C (with no icing)
Ambient humidity 45% to 85%
Certified standards G3H: UL508, CSA C22.2 No. 14, EN60947-4-3
G3HD: UL508, CSA C22.2 No. 14, EN60950-1
EMC Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
Weight Approx. 50 g
Load Current vs.
Ambient Temperature
Characteristics
One Cycle Surge Current: Non-repetitive
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3H-203SN-VD/203S-VD/203SLN-VD/
203SL-VD
G3HD-X03SN-VD/X03S-VD
G3HD-202SN-VD
G3H-203SN-VD/203S-VD/203SLN-VD/
G3H-203SL-VD
G3HD-X03SN-VD/X03S-VD
G3HD-202SN-VD
3020 0 20 40 60 80 100
0
1
1.5
2
2.5
3
4
Ambient temperature (°C)
Load current (A)
G3H-203SN-VD, G3H-203S-VD
G3H-203SLN-VD, G3H-203SL-VD
G3HD-X03SN-VD, G3HD-X03S-VD
G3HD-202SN-VD
10 30 50 100 200 500 1,000 5,000
0
10
40
20
50
30
Inrush current (A, Peak)
Energized time (ms)
10 20 30
50 70 100 200 300 500
1,000 2,000
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
G3HD-202SN-VD
G3HD-X03SN-VD
G3HD-X03S-VD
Energized time (ms)
Inrush current (A)

G3H-203SN DC5-24

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Solid State Relays - Industrial Mount SOLID STATE RELAY
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union