RAC03-09SC

Specifications
(measured at TA 25°C, full load after warm-up)
RAC03-C
POWERLINE
AC/DC-Converter
with 3 year Warranty
RAC03-SC
3 Watt
Single
Output
Ultracompact Low Profile AC-DC Power Supply
3 Watt PCB Mount Package
Universal Input Voltage Range
Class II Power Supply with 3kVAC Isolation
Only 80mW Consumption in Standby
-25°C to +85°C Operating Temperature
Low Output Ripple/Noise
Short Circuit Protected Outputs
EN, UL and CE Certified
Features
Regulated
Converters
Selection Guide
Input Voltage Range (with derating) 80-264VAC or 115-370VDC
Rated Power 3 Watts max.
Input Frequency Range (for AC Input) 47-63Hz
Input Current (full load) 115/230VAC 85mA/40mA max.
No Load Power Consumption 80mW typ.
Inrush Current (<0.5ms) 115/230VAC 30/60A max.
Leakage Current 0.85mA max.
Output Voltage Tolerance (combined Tolerance, Line Reg and Load Reg at full load) ±5% max.
Line Voltage Regulation low line, high line at full load ±3% max.
Load Voltage Regulation 10% to 100% full load ±6% max.
Output Ripple and Noise 3.3V, 3.8V, 5V Output 120mVp-p max.
(20MHz BW limited) All others 150mVp-p max.
Operating Frequency @ full load 35kHz typ
Hold-up Time 115 VAC 15ms typ.
230VAC 80ms typ.
Minimum Load = 0% specifications valid for 10% minimum load only
RMS Isolation Voltage input to output 3kVAC / 1 minute
Isolation Resistance input to output 1 GΩ min.
Isolation Capacitance input to output 1000pF typ.
Short Circuit Protection Hiccup, Automatic Restart
Over Voltage Category OVC II
Operating Temperature Range
(3)
(natural convection, without derating) -25°C to +75°C
(natural convection, with derating) -25°C to +85°C
Storage Temperature Range -40°C to +100°C
Humidity non-condensing 95% RH max
Case Material Plastic Case, Silicon filled (UL94V-0)
Package Weight 30g
Packing Quantity 12 pcs
EMC Conducted and Radiated EN 55022 Class B
Noise Immunity EN 55024
continued on next page
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25
0
50
60
70
80
90 100
Output Power (%)
Natural Convection
75
85
Description
The RAC03-SC series is an ultra-compact universal input AC/DC power
module for PCB mounting. It features high efficiency, low standby power,
high operating temperature, soft start, low output ripple/noise, overload
and short-circuit protection as well as a built-in EMC Class B filter. Output
voltages range from 3.3VDC to 24VDC, including a 3.8VDC version
designed for battery chargers and GSM modems.
Part Input Output Output Efficiency Max
Number Range Voltage Current Capacitive
(VAC) (VDC) (mA) (%) Load
(1+2)
RAC03-3.3SC 80-264 3.3 900 67 6800µF
RAC03-3.8SC 80-264 3.8 900 67 6800µF
RAC03-05SC 80-264 5 600 72 4000µF
RAC03-09SC 80-264 9 333 76 3000µF
RAC03-12SC 80-264 12 250 76 680µF
RAC03-15SC 80-264 15 200 76 470µF
RAC03-24SC 80-264 24 125 78 200µF
EN-60950-1 Certified
UL-60950-1 Certified
E224736
RoHS
2011/65/EU
6/6
Refer to Application Notes
Derating-Graph
(Ambient Temperature)
PA-6 www.recom-power.comREV: 0/2015
RAC03-SC
POWERLINE
AC/DC-Converter
Standard Package Style and Pinning
Pin Connections
Pin # Single Output
1 VAC in (L)
3 VAC in (N)
13 NC
14 -VDC out
16 +VDC out
NC = No Connection
1
Bottom View
Top View
13
3
14
16
20.32
5.08
5.08
17.78
23.90
2.54
1.20
ø
+0.2/0.1
5.0
37.80
15.65
6.1
2.54
ø
1.0
16.40
+0.25
-
0.75+0.25
-
Standoff height
Leave Clear
of
PCB Traces
Tolerance ± 0.5 mm
unless otherwise specified
Recommended Application Circuit
N
Load
C1(Optional)
330uF
L
1A Fuse
MOV
- required for
230VAC Surge
Protection only
Add C1 to reduce output ripple (use low ESR type)
VACin (L)
VACin (N)
Vout+
Vout-
RAC03-05SC
Compact single output regulated power supply
Suggested fuse rating: 1A Slow Blow
An external MOV is required for 230VAC operation. The varistor should comply with IEC-61051-2. e.g. Epcos S14 Series
Specifications
(measured at TA 25°C, full load after warm-up)
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
230VAC
115VAC
RAC03-05SC
RAC03-SC
Series
Input Voltage Derating Graph
Input Voltage Derating Graph
Load (%)
Input Voltage (VAC) Ta=25°C
Safe Operating Area
100%
90%
80%
70%
80
130 180
230
280
90V, 100%
80V, 85%
264V, 100%
Notes:
Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contace RECOM for detailed information.
Note3: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
MTBF +25°C >550 x 10
3
hours
230VAC +55°C >285 x 10
3
hours
using MIL-HDBK-217F +80°C >76 x 10
3
hours
Certifications:
UL General Safety File Nr. E224736 UL-60950-1, 2nd Edition
EN General Safety SPCLVD 1202026 EN-60950-1, 2nd Edition
CE Report: T110809202-E EN55022 Class B
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com PA-7REV: 0/2015

RAC03-09SC

Mfr. #:
Manufacturer:
RECOM Power
Description:
Switching Power Supplies CONV AC/DC 3W 80-264VIN 09VOUT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS