RSO-2415DZ/H2

ECONOLINE
DC/DC-Converter
with 3 year Warranty
RSO
Description
High-power-density, an industrial temperature range of -40°C to +85°C and extra features like
On-Off-control are just some of the characteristics of this converter, ideal for highly sophisticated
industrial-designs. The RSO series is available with isolation of 2kV or 3kV by choosing option "/H2"
or "/H3" in which case it is also ideal for medical applications which additionally require EN-60601-
1 certification. The standard version offers 2:1 input voltage range, while the “Z” version features 4:1
input voltage range, which includes an input voltage range covering both 5V and 12V supplies.
1 Watt
SIP8 Isolated
Single
& Dual
Output
2:1 and 4:1 Wide Input Voltage Ranges
1kVDC, 2kVD or 3kVDC Isolation
UL94V-0 Package Material
Certified for Medical Applications
Continuous Short Circuit Protection
Low Noise
No External Capacitor needed
Efficiency to 83 %
Features
Regulated
Converters
Selection Guide
Part Number Input Rated Output Output Current Efficiency Max
Voltage Range Voltage typ. Capacitive
SIP8 (VDC) (VDC) (mA) (%) Load
(1)
RSO-xx3.3S* 4.5-9**, 9-18 3.3 300 68-72 3300µF
18-36, 36-72 70
RSO-xx05S* 4.5-9**, 9-18 5 200 73-75 1200µF
18-36, 36-72 75-78
RSO-xx09S* 4.5-9**, 9-18 9 111 74-78 680µF
18-36, 36-72 78-81
RSO-xx12S* 4.5-9**, 9-18 12 83 75-80 680µF
18-36, 36-72 80-83
RSO-xx15S* 4.5-9**, 9-18 15 67 75-80 680µF
18-36, 36-72 80-83
RSO-xx3.3D* 4.5-9**, 9-18 ±3.3 ±150 68-72 ±1500µF
18-36, 36-72 70
RSO-xx05D* 4.5-9**, 9-18 ±5 ±100 73-75 ±470µF
18-36, 36-72 75-76
RSO-xx09D* 4.5-9**, 9-18 ±9 ±56 74-78 ±470µF
18-36, 36-72 78
RSO-xx12D* 4.5-9**, 9-18 ±12 ±42 75-79 ±330µF
18-36, 36-72 79-80
RSO-xx15D* 4.5-9**, 9-18 ±15 ±34 75-79 ±330µF
18-36, 36-72 79-80
RSO-xx3.3SZ* 9-36 3.3 300 68-70 3300µF
18-72 70
RSO-xx05SZ* 4.5-18**, 9-36 5 200 73-78 1200µF
18-72 75
RSO-xx09SZ* 4.5-18**, 9-36 9 111 75-81 680µF
18-72 78
RSO-xx12SZ* 4.5-18**, 9-36 12 83 77-83 680µF
18-72 80
RSO-xx15SZ* 4.5-18**, 9-36 15 67 78-83 680µF
18-72 80
RSO-xx3.3DZ* 9-36 ±3.3 ±150 70-74 ±1500µF
18-72 70
RSO-xx05DZ* 4.5-18**, 9-36 ±5 ±100 73-77 ±470µF
18-72 75
RSO-xx09DZ* 4.5-18**, 9-36 ±9 ±56 74-78 ±470µF
18-72 78
RSO-xx12DZ* 4.5-18**, 9-36 ±12 ±42 75-80 ±330µF
18-72 80
RSO-xx15DZ* 4.5-18**, 9-36 ±15 ±34 75-80 ±330µF
18-72 80
No suffix is standard isolation (1kVDC) e.g, RSO-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RSO-0505S/H2, RSO-0505DZ/H3
** derate to 75% if Vin<5V, 12V 4:1 input also requires an external 10µF input capacitor.
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
30
75
2:1
4:1
Derating-Graph
(Ambient Temperature)
2:1 Input 4:1 Input
(RS0-S/D) (RSO-SZ/DZ)
xx = 4.5-9Vin = 05 xx = 4.5-18Vin = 12
xx = 9-18Vin = 12 xx = 9-36Vin = 24
xx = 18-36Vin = 24 xx = 18-72Vin = 48
xx = 36-72Vin = 48
REV: 1/2017 E-123www.recom-power.com
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2: The RSO series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
RS0
Input Voltage Range 2:1 and 4:1
Output Voltage Accuracy ±2% typ.
Line Voltage Regulation 2:1 ±0.2% max.
4:1 ±0.5% max.
Load Voltage Regulation 2:1 ±0.4% max.
(10% to 100% full load) 4:1 ±0.5% typ.
Minimum Load 10%
(2)
Output Ripple and Noise (20MHz limited) 50mVp-p max.
Operating Frequency 2:1 200kHz min. / 500kHz max.
4:1 100kHz min. / 800kHz max.
Efficiency at Full Load See Selection Guide
Quiescent Current RSO-05xxS_D, SZ_DZ 40mA typ.
Nominal input Voltage RSO-12xxS_D, SZ_DZ 32mA typ.
(Standard, /H2 and /H3) RSO-24xxS_D, SZ_DZ 25mA typ.
RSO-48xxS_D, SZ_DZ 15mA typ.
CTRL Pin drive current /see Notes) 3mA typ, 6mA max.
Quiescent Input Current when Converter is OFF 10mA max.
Isolation Voltage Standard (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
/H2 Version (tested for 1 second) 2000VDC
(rated for 1 minute**) 1000VAC / 60Hz
/H3 Version (tested for 1 second) 3000VDC
(rated for 1 minute**) 1500VAC / 60Hz
Isolation Capacitance Standard 2:1 Single 10pF min. / 40pF typ. / 60pF max.
Isolation Capacitance /H2 and /H3 2:1 Single 5pF min. / 30pF typ. / 60pF max.
Isolation Capacitance Standard 2:1 Dual 120pF min. / 170pF typ. / 250pF max.
Isolation Capacitance /H2 and /H3 2:1 Dual 5pF min. / 30pF typ. / 60pF max.
Isolation Capacitance Standard 4:1 Single/Dual 200pF max.
Isolation Capacitance /H2 and /H3 4:1 Single/Dual 30pF max.
Isolation Resistance >1GΩ min.
Short Circuit Protection Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 4.7g
Packing Quantity 22 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1685 x 10
3
hours
(+85°C) using MIL-HDBK 217F 254 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1605077-10 EN60950-1, AM2:2013
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL General Safety Report: E224736-A34 UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
Specifications (Core Operating Area) measured at T
A
= 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2405
2412
2409
2415
RSO-24xxS
}
Detailed Information see
Application Notes chapter "MTBF"
RSO-S_D(Z)
Series
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
1205SZ
RSO-1205SZ
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please
refer to our Application Notes.
REV: 1/2017 www.recom-power.comE-124
RSO
8 PIN SIP Package
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
CTRL Examples:
Pin 8 (NC*) This pin is used internally and must have no external connection.
Pin 5 (NC) Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode.
When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is
ON. There is no allowed low state for this pin.
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
12 53678
3.20
0.32
2.0
9.20
21.80
RECOM
RSO-xxxxS_D
****
12 53678
0.50±0.05
4.1
0.50±0.05
11.10
RECOM
RSO-xxxxS
****
RECOM
RSO-xxxxD
****
2.54
2.54
1.0
ø
+0.15/0
Top View
Bottom View
Single Output
Dual Output
Recommended Footprint Details
Pin Connections
Pin # Single Dual
1 –Vin –Vin
2 +Vin +Vin
3 CTRL CTRL
5NC NC
6 +Vout +Vout
7 –Vout Com
8 NC* –Vout
NC = No Connection
NC* = NC, but no external Connection allowed.
V+
LEAVE OPEN
V
IN+
CTRL
VIN-
10K
ON
OFF
FET.
V-
RSO-S_D(Z)
Series
-Vin
-Vout
+Vout
+Vin
CTRL
5~12
1N4148
68
3
Typical Application
-Vin
-Vout
+Vout
+Vin
RSO
10µF input MLCC
capacitor
required for
RSO-12xxSZ_DZ
only.
Vin+
Vin-
Vout+
Vout-
Fuse
ON/OFF CONTROL
I = 3V
O = 0.5V or GND
Remote ON/OFF ON: open or high impedance
OFF: external 5~12 Vdc and 1N4148+ 68 resistor
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV: 1/2017 E-125www.recom-power.com

RSO-2415DZ/H2

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 1W DC/DC 2kV REG 4:1 9-36Vin +/-15Vout
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union