Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2: The RSO series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
RS0
Input Voltage Range 2:1 and 4:1
Output Voltage Accuracy ±2% typ.
Line Voltage Regulation 2:1 ±0.2% max.
4:1 ±0.5% max.
Load Voltage Regulation 2:1 ±0.4% max.
(10% to 100% full load) 4:1 ±0.5% typ.
Minimum Load 10%
(2)
Output Ripple and Noise (20MHz limited) 50mVp-p max.
Operating Frequency 2:1 200kHz min. / 500kHz max.
4:1 100kHz min. / 800kHz max.
Efficiency at Full Load See Selection Guide
Quiescent Current RSO-05xxS_D, SZ_DZ 40mA typ.
Nominal input Voltage RSO-12xxS_D, SZ_DZ 32mA typ.
(Standard, /H2 and /H3) RSO-24xxS_D, SZ_DZ 25mA typ.
RSO-48xxS_D, SZ_DZ 15mA typ.
CTRL Pin drive current /see Notes) 3mA typ, 6mA max.
Quiescent Input Current when Converter is OFF 10mA max.
Isolation Voltage Standard (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
/H2 Version (tested for 1 second) 2000VDC
(rated for 1 minute**) 1000VAC / 60Hz
/H3 Version (tested for 1 second) 3000VDC
(rated for 1 minute**) 1500VAC / 60Hz
Isolation Capacitance Standard 2:1 Single 10pF min. / 40pF typ. / 60pF max.
Isolation Capacitance /H2 and /H3 2:1 Single 5pF min. / 30pF typ. / 60pF max.
Isolation Capacitance Standard 2:1 Dual 120pF min. / 170pF typ. / 250pF max.
Isolation Capacitance /H2 and /H3 2:1 Dual 5pF min. / 30pF typ. / 60pF max.
Isolation Capacitance Standard 4:1 Single/Dual 200pF max.
Isolation Capacitance /H2 and /H3 4:1 Single/Dual 30pF max.
Isolation Resistance >1GΩ min.
Short Circuit Protection Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 4.7g
Packing Quantity 22 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1685 x 10
3
hours
(+85°C) using MIL-HDBK 217F 254 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1605077-10 EN60950-1, AM2:2013
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL General Safety Report: E224736-A34 UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
Specifications (Core Operating Area) measured at T
A
= 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified
ECONOLINE