Document Number: 72552
S11-0179-Rev. C, 07-Feb-11
www.vishay.com
5
Vishay Siliconix
DG406B, DG407B
Notes:
a. Guaranteed by ± 15 V leakage test, not production tested.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
g. r
DS(on)
= R
DS(on)
MAX. - R
DS(on)
MIN.
h. Worst case isolation occurs on Channel 4 due to proximity to the drain pin.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONS FOR SINGLE SUPPLY
Parameter Symbol
Test Conditions
Unless Otherwise Specified
V+ = 12 V, V- = 0 V
V
AL
= 0.8 V, V
AH
= 2.4 V
f
Temp.
b
Typ.
c
A Suffix
- 55 °C to 125 °C
D Suffix
- 40 °C to 85 °C
Unit Min.
d
Max.
d
Min.
d
Max.
d
Analog Switch
Analog Signal Range
e
V
ANALOG
Full 0 12 0 12 V
Drain-Source
On-Resistance
R
DS(on)
V
D
= 3 V, I
S
= - 1 mA
sequence each switch on
Room 78 100 100
r
DS(on)
Matching Between
Channels
g
R
DS(on)
Room 5 %
Source Off Leakage Current
a
I
S(off) V
EN
= 0 V
V
D
= 10 V or 0.5 V
V
S
= 0.5 V or 10 V
Room - 0.5 0.5 - 0.5 0.5
nA
Drain Off Leakage Current
a
I
D(off)
DG406B Room - 1 1 - 1 1
DG407B Room - 1 1 - 1 1
Drain On Leakage Current
a
I
D(on)
V
S
= V
D
= ± 10 V
sequence each
switch on
DG406B Room - 1 1 - 1 1
DG407B Room - 1 1 - 1 1
Dynamic Characteristics
Switching Time of Multiplexer t
TRANS
V
S1
= 8 V, V
S8
= 0 V,
V
IN
= 2.4 V
Room 130 163 163
ns
Enable Turn-On Time t
ON(EN)
V
INH
= 2.4 V, V
INL
= 0 V
V
S1
= 5 V
Room 93 125 125
Enable Turn-Off Time t
OFF(EN)
Room 63 94 94
Charge Injection Q C
L
= 1 nF, V
S
= 6 V, R
S
= 0 Room 9 pC
Power Supplies
Positive Supply Current I+
V
EN
= 0 V or 5 V,
V
A
= 0 V or 5 V
Room
Full
13 30
75
30
75
µA
Negative Supply Current I-
Room
Full
- 0.01 - 20
- 20
- 20
- 20