L5954 Electrical specifications
Doc 17717 Rev 1 7/15
ΔV
line
Line regulation
11 V V
CC
26 V
(Measure Δ V
REG1
across V
CC
range)
--55mV
ΔV
load
Load regulation 5 mA I
REG1
350 mA - - 55 mV
V
DROPOUT
Dropout voltage (measure V
BAT
-
V
REG1
when V
REG1
drops 0.1 V)
(Measure V
BAT
- V
REG1
when
V
REG1
drops 0.1 V)
I
REG1
= 350 mA
I
REG1
= 5 mA
--
900
300
mV
mV
I
lim1
Current limit - 0.51 - 1.1 A
SVR Ripple rejection
f
o
= 1 kHz, V
BAT
= 14 V
with 1Vpp AC
I
REG1
= 175 mA
50 - - dB
8.5 V / 175 mA Reg 2 output
V
REG2
Output voltage
I
REG2
= 175 mA
9.5 V VB
AT
16 V
8.0 8.5 9.0 V
ΔV
line
Line regulation
9.5 V V
BAT
26 V
(Measure Δ V
REG2
across V
BAT
Range)
--50mV
ΔV
load
Load regulation 5 mA I
REG2
175mA - - 50 mV
V
DROPOUT
Dropout voltage
(Measure V
BAT
- V
REG2
when
V
REG2
drops 0.1 V)
I
REG2
= 175 mA
I
REG2
= 5 mA
--
900
300
mV
mV
I
lim2
Current limit - 280 - 525 mA
SVR Ripple rejection
f
o
= 1 kHz, V
BAT
= 14 V
with 1 Vpp AC
I
REG2
= 100 mA
50 - - dB
5 V / 350 mA Reg 3 output
V
REG3
Voltage offset from V
REF
- - 10 40 mV
ΔV
line
Line regulation
7 V V
BAT
26 V
(Measure Δ V
REG3
across V
BAT
range)
--50mV
ΔV
load
Load regulation 5 mA I
REG3
350 mA - - 100 mV
V
DROPOUT
Dropout voltage (Measure V
BAT
-
V
REG3
when V
REG3
drops 0.1V)
(Measure V
BAT
- V
REG3
when
V
REG3
drops 0.1 V)
I
REG3
= 175 mA
I
REG3
= 5 mA
--
950
600
mV
mV
I
lim3
Current limit - 0.5 - 1 A
SVR Ripple rejection
f
o
= 1 kHz, V
BAT
= 14 V
with 1 Vpp AC, I
REG3
= 175 mA
50 - - dB
Table 4. Electrical characteristics (continued)
Symbol Parameter Test Condition Min. Typ. Max. Unit
Obsolete Product(s) - Obsolete Product(s)
Electrical specifications L5954
8/15 Doc 17717 Rev 1
8/10 V/1 A Reg 4 output
V
REG4
Output voltage
I
REG4
= 1 A
b5 = 0
b5 = 1
7.6
9.50
8
10
8.4
10.5
V
V
ΔV
line
Line regulation
11 V V
BAT
26 V, b5 = 1
(Measure Δ V
REG2
across V
BAT
Range)
--50mV
ΔV
load
Load regulation 5 mA I
REG4
1 A - - 150 mV
V
DROPOUT
Dropout voltage
(Measure V
BAT
- V
REG2
when
V
REG2
drops 0.1 V)
I
REG4
= 1 A
I
REG4
= 5 mA
--
950
600
mV
mV
I
lim4
Current limit - 1.3 - 2.4 A
SVR Ripple rejection
f
o
= 1 kHz, V
BAT
= 14 V
with 1 Vpp AC, I
REG4
= 500 mA
50 - - dB
5 V/250 mA Reg 5 output
V
REG5
Output voltage I
REG5
= 250 mA 4.6 5 5.4 V
ΔV
line
Line regulation
7 V V
BAT
26 V
(Measure Δ V
REG5
across V
BAT
Range)
--40mV
ΔV
load
Load regulation 5 mA I
REG5
250 mA - - 100 mV
V
DROPOUT
Dropout voltage
(Measure V
BAT
- V
REG5
when
V
REG5
drops 0.1 V)
I
REG5
= 250 A
I
REG5
= 5 mA
--
1.6
1.2
V
V
I
lim5
Current limit - 320 - 700 mA
SVR Ripple rejection
f
o
= 1 kHz, V
BAT
= 14 V
with 1Vpp AC, I
REG5
= 125 mA
50 - - dB
2 A HSD1
V
sat
Output saturation voltage
I
HSD1
= 1 A continuous time
operation
--0.5V
I
leak1
Output leakage current All driver outputs are off -50 - 50 µA
I
lim
Current limiting R
HSD1
= 0.5 Ω 2.4 - 4 A
Table 4. Electrical characteristics (continued)
Symbol Parameter Test Condition Min. Typ. Max. Unit
Obsolete Product(s) - Obsolete Product(s)
L5954 Electrical specifications
Doc 17717 Rev 1 9/15
0.45A HSD2 and HSD3
V
sat
Output saturation voltage
I
HSD2,3
= 300 mA
Continuous time operation
--0.6V
I
leak2,3
Output leakage current All driver outputs are off -50 - 50 µA
I
lim
Current limiting R
HSD2,3
= 0.5 Ω 0.56 - 1 A
Characteristics for I
2
C
V
IL
Low level input voltage - - - 1.5 V
V
IH
High level input voltage - 3 - - V
V
HYS
Input hysteresis - 0.2 - - V
V
OL1
V
OL2
Low level output
Sink current = 3 mA
Sink current = 6 mA
--
0.4
0.6
V
V
I
I
Input current 0.4 V V
I
0.9 V
DDmax
-10 - 10 µA
f
SCL
SCL clock frequency - - - 400 kHz
Table 4. Electrical characteristics (continued)
Symbol Parameter Test Condition Min. Typ. Max. Unit
Obsolete Product(s) - Obsolete Product(s)

L5954

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
LDO Voltage Regulators MULTIFUNCTIONAL VOLTAGE REGULATO MULTIWATT 15L SPLIT VERT.
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet