7
PC4SF21YVZ Series
Fig.9 Turn-on Time vs. Forward Current
Sheet No.: D2-A08301EN
10
5
10
7
10
8
10
6
10
9
10020 0 20 60 8040
V
D
=800V
40
Ambient Temperature T
a
(˚C)
Repetitive peak OFF-state current I
DRM
(A)
Fig.8 Repetitive Peak OFF-state Current vs.
Ambient Temperature
1
10
100
110100
Turn-on time t
ON
(µs)
Forward current I
F
(mA)
V
D
=4V
R
L
=100
Fig.10-a Z
ero-cross Voltage vs. Ambient
Temperature (Rank B)
0
2
4
6
8
10
12
14
16
18
20
40 020 20 40 60 80 100
Zero-cross voltage V
OX
(V)
Ambient temperature T
a
(˚C)
Resistance load,
I
F
=15mA
Remarks : Please be aware that all data in the graph
are just for reference.
Fig.10-b Z
ero-cross Voltage vs. Ambient
Temperature (Rank C)
0
2
4
6
8
10
12
14
16
18
20
40 020 20 40 60 80 100
Zero-cross voltage V
OX
(V)
Ambient temperature T
a
(˚C)
Resistance load,
I
F
=8mA
Fig.7 Holding Current vs.
Ambient Temperature
0.01
0.1
1
Holding Current I
H
(mA)
Ambient temperature T
a
(˚C)
V
D
=4V
40 20 0 20 406080100
Recommended Foot Print (reference)
8
SMT Gullwing Lead-form Wide SMT Gullwing Lead-form
2.542.54
1.7
2.2
10.2
2.542.54
1.7
2.2
8.2
(Unit : mm)
PC4SF21YVZ Series
Sheet No.: D2-A08301EN
Design Considerations
In order for the Phototriac to turn off, the triggering current (I
F
) must be 0.1mA or less.
Please refrain from using these devices in a direct drive configuration. These Phototriac Coupler are
intended to be used as triggering device for main Triacs. Please ensure that the output rating of these
devices will be sufficient for triggering the main output Triac of your choice. Failure to do may result in
malfunctions.
For applications with inductive loads such as motors,please use caution in utilizing a zero crossing type
Phototraiac Coupler as this may cause undesired operations due to the phase difference between voltage
and current of load.
For designs that will experience excessive noise or sudden changes in load voltage, please include an
appropriate snubber circuit as shown in the below circuit. Please keep in mind the Sharp Phototriac Coupler
incorporate superrior dV/dt ratings which can eliminate the need for a snubber circuit.
For over voltage protection, a Varistor may be used.
Degradation
In general, the emission of the IRED used in Phototriac Couplers will degrade over time.
In the case where long term operation and / or constant extreme temperature fluctuations will be applied to
the devices, please allow for a worst case scenario of 50% degradation over 5years.
Therefore in order to maintain proper operation, a design implementing these Phototriac Couplers should
provide at least twice the minimum required triggering current from initial operation.
Design guide
9
PC4SF21YVZ Series
Sheet No.: D2-A08301EN
For additional design assistance, please review our corresponding Optoelectronic Application Notes.
Standard Circuit (Medium/High Power Triac Drive Circuit)
Triac
Load
PC4SF21YVZ
Note) Please add the snubber circuit according to a condition.
Any snubber or varistor used for the above mentioned scenarios should be located
as close to the main output triac as possible.
6
5
1
2
4
3
AC Line
Zero Crossing
Circuit

PC4SF21YVZCF

Mfr. #:
Manufacturer:
Sharp Microelectronics
Description:
Triac & SCR Output Optocouplers Phototriac ZC 800V 5mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet