Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 12 V DC
Why buy this product
Plugs can be checked with CHECKMASTER
Maximum ease of maintenance thanks to the two-piece design
Base element remains an integral part of the installation
Protection for fieldbus systems, PROFIBUS, and signal circuits with 3 to 5-wire technology
Consistent plug-in signal circuit protection
Impedance-neutral disconnection of plug for test and maintenance purposes
  
Key commercial data
Packing unit 1
Minimum order quantity 10
Catalog page Page 100 (TT-2011)
GTIN
Custom tariff number 85363010
Country of origin GERMANY
Technical data
General
Housing material PA
Inflammability class according to UL 94 V0
Color black
Standards for air and creepage distances DIN EN 61664-1
Standards for air and creepage distances IEC 60664-1
Surge voltage category III
Pollution degree 2
Total surge current (8/20) µs 20 kA
Ambient temperature (operation) -40 °C ... 85 °C
Mounting type On base element
https://www.phoenixcontact.com/us/produkte/2838775
05.10.2012Page2/7
Surge protection connector-PT 5-HF-12DC-ST-2838775
Technical data
General
Design DIN rail module, two-section, divisible
Number of positions 5
Degree of protection IP20
Direction of action
Line-Line & Line-Signal Ground/Shield & optional Signal Ground/
Shield-Earth Ground
Arrester can be tested with CHECKMASTER from software
version:
From SW rev. 1.00
Width 17.7 mm
Height 45 mm
Depth 52 mm
Pitch unit 1 Div.
Protective circuit
IEC category C1
IEC category C2
IEC category C3
IEC category D1
VDE requirement class C1
VDE requirement class C2
VDE requirement class C3
VDE requirement class D1
Nominal voltage UN 12 V DC
Maximum continuous operating voltage UC 14 V DC
Maximum continuous operating voltage UC 9.8 V AC
Maximum continuous voltage UC (wire-wire) 14 V DC
Maximum continuous voltage UC (wire-wire) 9.8 V AC
Maximum continuous voltage UC (wire-ground) 14 V DC (with PT 2x2-BE)
Nominal current IN 450 mA (45°C)
Operating effective current IC at UC ≤ 5 µA
Ground conductor current IPE ≤ 5 µA (with PT 2x2-BE)
Ground conductor current IPE ≤ 1 µA (with PT 2x2+F-BE)
Nominal discharge surge current In (8/20) µs (Core-Core) 10 kA
Nominal discharge surge current In (8/20) µs (Core-Earth) 10 kA
Total surge current (8/20) µs 20 kA
Max. discharge surge current Imax (8/20) µs maximum (Core-
Core)
10 kA
Max. discharge surge current Imax (8/20) µs maximum (Core-
Earth)
10 kA
Nominal pulse current Ian (10/1000) µs (Core-Core) 67 A
Lightning test current (10/350) µs, peak value limp 2.5 kA
Output voltage limitation at 1 kV/µs (Core-Core) spike ≤ 55 V
Output voltage limitation at 1 kV/µs (Core-Earth) spike ≤ 55 V (PT 2x2-BE)
Output voltage limitation at 1 kV/µs (Core-Earth) spike ≤ 700 V (with PT 2x2+F-BE)
Output voltage limitation at 1 kV/µs (Core-Core) static ≤ 25 V
https://www.phoenixcontact.com/us/produkte/2838775
05.10.2012Page3/7
Surge protection connector-PT 5-HF-12DC-ST-2838775
Technical data
Protective circuit
Output voltage limitation at 1 kV/µs (Core-Earth) static ≤ 25 V
Output voltage limitation at 1 kV/µs (Core-Earth) static ≤ 40 V (PT 2x2+F-BE)
Residual voltage at In, (conductor-conductor) ≤ 25 V
Residual voltage at In, (conductor-ground) ≤ 40 V (with PT 2x2-BE)
Residual voltage at In, (conductor-GND) ≤ 25 V (with PT 2x2-BE)
Residual voltage with Ian (10/1000)µs (conductor-conductor) ≤ 25 V
Residual voltage with Ian (10/1000)µs (conductor-GND) ≤ 25 V
Protection level UP (Core-Core) ≤ 100 V (C2 (10 kV/5 kA))
Protection level UP (Core-Core) ≤ 45 V (C3 - 25 A)
Protection level UP (Core-Earth) ≤ 100 V (C2 (10 kV/5 kA) with BE 2839208)
Protection level UP (Core-Earth) ≤ 600 V (C2 (10 kV/5 kA) with BE 2839224)
Protection level UP (Core-Earth) ≤ 45 V (C3 - 25 A)
Protection level UP (Core-GND) ≤ 45 V (C3 - 25 A)
Response time tA (Core-Core) ≤ 500 ns
Response time tA (Core-Earth) ≤ 500 ns
Input attenuation aE, sym. Typ. 0.2 dB (≤ 5 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm system Typ. 70 MHz
Capacity (Core-Core) Typ. 30 pF
Resistance in series 2.2 Ω ±10 %
Max. required back-up fuse 500 mA (e.g. T in acc. with IEC 127-2/III)
Surge carrying capacity in acc. with IEC 61643-21 (Core-Core) C2 (10 kV/5 kA)
Surge carrying capacity in acc. with IEC 61643-21 (Core-Core) C3 (67 A)
Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth) C2 (10 kV/5 kA)
Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth) C3 (67 A)
Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth) D1 (2.5 kA)
Connection data
Connection method Screw connection (in connection with the base element)
Connection type IN PLUGTRAB plug-in system
Connection type OUT PLUGTRAB plug-in system
Classifications
eclass
eCl@ss 4.0 27140201
eCl@ss 4.1 27130801
eCl@ss 5.0 27130801
eCl@ss 5.1 27130801
eCl@ss 6.0 27130807
eCl@ss 7.0 27130807
etim
ETIM 2.0 EC000943

2838775

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Surge Suppressors PT 5-HF-12DC-ST
Lifecycle:
New from this manufacturer.