Contact Ratings
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Coil Data
Nominal Coil Voltage 24 120 208/240 277 480
Maximum Pickup Volts 18 88 177 220 384
Drop-Out Volts Range 6 -15 20 - 70 40 - 140 65 - 185 150 - 270
Nominal Inrush VA @ 50 Hz 60 60 60 60 65
Nominal Inrush VA @ 60 Hz 53 53 53 53 53
Nominal Sealed VA @ 50 Hz 6.0 6.0 6.0 6.0 6.0
Nominal Sealed VA @ 60 Hz 5 5 5 5 5
Nominal DC Resistance - Ohms 7 180 720 950 3100
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Full Number Line Locked Resistive Maximum Horsepower
Load of Voltage Rotor Amps Voltage Single Three
Amps Poles Amps Rating Phase Phase
240/277 120 30 110/120 1.5 -
20 3 480 100 30 200/240 3 7.5
600 80 30 480/600 - 7.5
110/120 2 -
240/277 150 35 200/208 - 7.5
25 3 480 125 35 240/277 5 10
600 100 35 480 - 15
600 - 20
110/120 2 -
240/277 180 40 200/208 - 10
30 3 480 150 40 240/277 5 10
600 120 40 480 - 15
600 - 20
110/120 3 -
240/277 240 50 200/208 - 10
40 3 480 200 50 240/277 7.5 10
600 160 50 480 - 20
600 - 25
Contact Data @ 25°C
Arrangements: 3 Form X (3PST-NO-DM).
Maximum Ratings: See Contact Ratings Table.
Material: Silver Cadmium Oxide.
Coil Data @ 25°C
Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class: UL Class B (130°C).
Duty Cycle: Continuous.
Environmental Data
Temperature Range: Storage and Operating: -40°C – +65°C.
Flammability: UL 94-HB housing.
Mechanical Data
Contact Termination:
20, 25, 30 FLA Models
Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque: 25 in.-lbs.
40 FLA Models
Type: Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size: 14-4 Cu/Al AWG
Tightening Torque: 40 in.-lbs.
Coil Termination: Dual 0.250” (6.35 mm) quick connects, standard.
A 0.250” quick connect and a #6-32 screw, optional.
Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models.
Weight: 16 oz. (455 g) approximately
Model 98 - 3100series
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1