cui.com
date 08/29/2012 │ page 2 of 5CUI Inc │ SERIES: VYB10W │ DESCRIPTION: DC-DC CONVERTER
INPUT
parameter conditions/description min typ max units
operating input voltage
9
18
24
48
36
72
Vdc
Vdc
start up time nominal imput, full load 180 ms
fi lter PI type
OUTPUT
parameter conditions/description min typ max units
line regulation measured from low line to high line ±0.2 ±0.5 %
load regulation measured from 10% to full load ±0.5 ±1
1
%
voltage accuracy
positive, refer to recommended circuit
negative, refer to recommended circuit
±1
±3
±3
±5
%
%
transient recovery time
25% load step change (PWM type)
25% load step change (PFM type)
200
10
500
20
ms
ms
transient peak deviation ±3 ±5 %
cross regulation main output 55% supplemental output from 10-100% ±5 %
switching frequency 100% load, input voltage range 300 kHz
temperature coeffi cient ±0.03 %/°C
Notes: 1. Dual output models unbalanced load: ±5%
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage tested for 1 minute at 1 mA max. 1,500 Vdc
isolation resistance at 500 Vdc 1,000
MΩ
isolation capacitance input to output, 100 kHz / 1 V 1,000
pF
RoHS compliant yes
MTBF 1,000,000 hours
ENVIRONMENTAL
parameter conditions/description min typ max units
case operating temperature -40 85 °C
maximum case temperature during operation 105 °C
storage temperature -55 105 °C
storage humidity non-condensing 95 %
temperature rise 100% load 40 °C
lead temperature 1.5 mm from the case for 10 seconds 300 °C
For more information, please visit the product page.