DC-DC
Specification
8/10 Watts
• 2:1 Input Range
• DIP-24 Metal Package
• O
perating Temperature -40 °C to +100 °C
• Single & Dual Outputs
• Continuous Short Circuit Protection
• 1500 VDC Isolation
• 3 Year Warranty
JCJ Series
Input
Input Voltage Range • 12 V (9-18 VDC)
24 V (18-36 VDC
48 V (36-75 VDC)
Input Current • See table
Input Filter • Pi network
Input Reflected • JCJ08: 35 mA, JCJ10: 20 mA
Ripple Current pk-pk through 12 µH inductor
Input Surge • 12 V models 24/25 VDC for 100 ms
24 V models 40/50 VDC for 100 ms
48 V models 100 VDC for 100 ms
Undervoltage Lockout • None
Reverse Voltage • None
Protection
Output
Output Voltage • See table
Output Voltage Balance • ±1% max, dual output models
Minimum Load • No minimum load required
Initial Set Accuracy • ±1% max
Line Regulation • ±0.5% max
Load Regulation • ±0.7% for 2.5-3.3 V models, ±0.5% for all
other models (see note 2)
Cross Regulation • ±5% on dual output models (see note 3)
Transient Response • <3% max deviation, recovery to within 1%
in 200 µs for a 25% load change
Ripple & Noise • 75 mV pk-pk, 20 MHz bandwidth,
(see note 4)
Overvoltage Protection • JCJ10: 3.3 V models: 3.9 V typ.,
5 V models: 6.2 V typ.,
12 V models: 15.0 V typ.,
15 V models: 18.0 V typ.,
±12 V models: ±15.0 V typ.,
±15 V models: ±18.0 V typ.
JCJ08: No OVP
Overload Protection • >150% of full load
Short Circuit Protection • Trip & restart (hiccup) with auto recovery
Maximum Capacitive • See tables
Load
Temperature • ±0.02/°C max
Coefficient
xppower.com
General
Efficiency • See tables
Isolation • 1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
Isolation Capacitance • 1200 pF max
Switching Frequency • 330 kHz typical
Power Density • JCJ10: 25 W/in
3
JCJ08: 20 W/in
3
MTBF • >900 KHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • -40 °C to +100 °C, derate from 100% load
at +60 °C to no load at +100 °C
Case Temperature • +100 °C max
Storage Temperature • -40 °C to +125 °C
Humidity • Up to 95% RH, non-condensing
Cooling • Natural convection
EMC
Emissions • EN55022 Class A conducted
& radiated with external components,
see application note
ESD Immunity • EN61000-4-2, 8 kV air discharge,
4 kV contact discharge
JCJ10: 6 kV contact discharge,
Perf Criteria A
EFT/Burst • EN61000-4-4, level 1
JCJ10: level 3, Perf Criteria A, (see note 5)
Surge • JCJ08: EN61000-4-5, installation class 2,
JCJ10: installation class 3,
Perf Criteria A, (see note 5)
Conducted Immunity • EN61000-4-6, 3 Vrms
JCJ10: 10 Vrms, Perf Criteria A
Magnetic Field • EN61000-4-8, 1 A/m Perf Criteria A