Maximum ratings LD39030SJ
6/18 DocID18103 Rev 5
4 Maximum ratings
Note: Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these conditions is not implied. All values are referred to GND.
Table 3. Absolute maximum ratings
Symbol Parameter Value Unit
V
IN
DC input voltage - 0.3 to 6 V
V
OUT
DC output voltage - 0.3 to V
IN
+ 0.3 V
V
EN
Enable input voltage - 0.3 to V
IN
+ 0.3 V
I
OUT
Output current Internally limited mA
P
D
Power dissipation Internally limited mW
T
STG
Storage temperature range - 65 to 150 °C
T
OP
Operating junction temperature range - 40 to 125 °C
Table 4. Thermal data
Symbol Parameter Value Unit
R
thJA
Thermal resistance junction-ambient 180 °C/W