4
Recommended Codewheel and Codestrip Characteristics
Parameter Symbol Min. Max. Unit Notes
Window/bar Ratio Ww/Wb 0.9 1.1
Window/bar Length L
W
1.80 (0.071) 2.31 (0.091) mm (inches)
Specular Reectance R
f
60 - Reective area.
See note 1.
- 10 Non reective area
Line Density LPmm (LPI) 10 (254)
12.5 (318)
lines/mm (inch)
Optical radius Rop 11 - mm Recommended
Rop=11.0mm
Notes:
1. Measurements from SMS µScan System. Contact factory for more information.
2. Contact factory for more information on compatibility of codewheel/strip.
Encoding Characteristics
Encoding characteristics over the recommended operating condition and mounting conditions.
Parameter Symbol Typical Maximum Unit
Pulse Width Error (Channel A) ∆P 10 75 °e
Pulse Width Error (Channel B) ∆P 11 80 °e
Phase Error
∆φ
7 60 °e
Note:
1. Typical values represent the encoder performance at typical mounting alignment, whereas the maximum values represent the encoder perfor-
mance across the range of recommended mounting tolerance.
Electrical Characteristics
Characteristics over recommended operating conditions at 25°C.
Parameter Symbol Min. Typ. Max. Unit Notes
Detector Supply Current Icc 6.0 7.0 mA
High Level Output Voltage V
OH
2.4 V I
OH
= -0.2mA
Low Level Output Voltage V
OL
0.4 V I
OL
= 8.0mA
Rise Time t
r
400 ns C
L
= 25pF
Fall Time t
f
120 ns R
L
= 2.7kW
L
W
W
W
, Reective area
W
b
, Non-reective area
W
W
= W
B
= 50µm (254LPI)
Codestrip