Data Sheet ADuM4400/ADuM4401/ADuM4402
Rev. D | Page 7 of 20
PACKAGE CHARACTERISTICS
Table 13.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input to Output)
1
R
I-O
10
12
Ω
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
33 °C/W Thermocouple located at
center of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
28 °C/W
1
Device considered a 2-terminal device: Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14, Pin 15, and
Pin 16 shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM440x are approved by the organizations listed in Table 14. Refer to Table 19 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 14.
UL CSA VDE
Recognized under 1577 Component
Recognition Program
1
Approved under CSA Component
Acceptance Notice #5A
Certified according to DIN V VDE V 0884-10 (VDE V
0884-10): 2006-12
2
Single Protection
5000 V rms Isolation Voltage
Basic insulation per CSA 60950-1-07 and IEC
60950-1, 600 V rms (848 V peak) maximum
working voltage
Reinforced insulation, 846 V peak
RW-16 package:
Reinforced insulation per CSA 60950-1-07
and IEC 60950-1, 380 V rms (537 V peak)
maximum working voltage; reinforced
insulation per IEC 60601-1 125 V rms (176 V
peak) maximum working voltage
RI-16 package:
Reinforced insulation per CSA 60950-1-07
and IEC 60950-1, 400 V rms (565 V peak)
maximum working voltage; reinforced
insulation per IEC 60601-1 250 V rms (353 V
peak) maximum working voltage
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL1577, each ADuM440x is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM440x is proof tested by applying an insulation test voltage ≥1590 V peak for 1 sec (partial discharge detection limit
= 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 15.
Parameter Symbol
Value Unit Conditions
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap L(I01) 8.0 min mm Distance measured from input terminals to output
terminals, shortest distance through air along the PCB
mounting plane, as an aid to PC board layout
Minimum External Tracking (Creepage) RW-16 Package L(I02) 7.7 min mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum External Tracking (Creepage) RI-16 Package L(I02) 8.3 min mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
ADuM4400/ADuM4401/ADuM4402 Data Sheet
Rev. D | Page 8 of 20
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
means of protective circuits.
Note that the * marking on packages denotes DIN V VDE V 0884-10 approval for 846 V peak working voltage.
Table 16.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 300 V rms I to IV
For Rated Mains Voltage 450 V rms I to II
For Rated Mains Voltage ≤ 600 V rms I to II
Climatic Classification 40/105/21
Pollution Degree (DIN VDE 0110, Table 1) 2
Maximum Working Insulation Voltage V
IORM
846 V peak
Input-to-Output Test Voltage, Method b1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1590 V peak
Input-to-Output Test Voltage, Method a V
PR
After Environmental Tests Subgroup 1 V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 1375 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 1018 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
6000 V peak
Safety-Limiting Values Maximum value allowed in the event of a failure;
see Figure 4
Case Temperature T
S
150 °C
Side 1 Current I
S1
265 mA
Side 2 Current I
S2
335 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150 200
SIDE #1
SIDE #2
08157-004
Figure 4. Thermal Derating Curve, Dependence of Safety Limiting
Values with Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 17.
Parameter Symbol Min Max Unit
Operating Temperature T
A
40 +105 °C
Supply Voltages
1
V
DD1
, V
DD2
3.0 5.5 V
Input Signal Rise and Fall Times
1.0
ms
1
All voltages are relative to their respective ground.
Data Sheet ADuM4400/ADuM4401/ADuM4402
Rev. D | Page 9 of 20
ABSOLUTE MAXIMUM RATINGS
Table 18.
Parameter Rating
Storage Temperature (T
ST
) 65°C to +150°C
Ambient Operating Temperature (T
A
)
40°C to +105°C
Supply Voltages (V
DD1
, V
DD2
)
1
0.5 V to +7.0 V
Input Voltage (V
IA
, V
IB
, V
IC
, V
ID
, V
E1
, V
E2
)
1, 2
0.5 V to V
DDI
+ 0.5 V
Output Voltage (V
OA
, V
OB
, V
OC
, V
OD
)
1, 2
0.5 V to V
DDO
+ 0.5 V
Average Output Current Per Pin
3
Side 1 (I
O1
) 18 mA to +18 mA
Side 2 (I
O2
) 22 mA to +22 mA
Common-Mode Transients
4
100 kV/µs to +100 kV/µs
1
All voltages are relative to their respective ground.
2
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PC Board Layout section.
3
See Figure 4 for maximum rated current values for various temperatures.
4
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the Absolute Maximum Rating can cause latch-
up or permanent damage.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
ESD CAUTION
Table 19. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar Waveform 565 V peak
50 year minimum lifetime
AC Voltage, Unipolar Waveform
Reinforced Insulation 846 V peak
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
DC Voltage
Reinforced Insulation 846 V peak
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Table 20. Truth Table (Positive Logic)
V
Ix
Input
1
V
Ex
Input
V
DDI
State
1
V
DDO
State
1
V
Ox
Output
1
Notes
H H or NC Powered Powered H
L H or NC Powered Powered L
X L Powered Powered Z
X H or NC Unpowered Powered H Outputs return to input state within 1 µs of V
DDI
power restoration.
X L Unpowered Powered Z
X X Powered Unpowered Indeterminate Outputs return to input state within 1 µs of V
DDO
power restoration if
V
Ex
state is H or NC. Outputs return to high impedance state within
8 ns of V
DDO
power restoration if V
Ex
state is L.
1
V
Ix
and V
Ox
refer to the input and output signals of a given channel (A, B, C, or D). V
Ex
refers to the output enable signal on the same side as the V
Ox
outputs. V
DDI
and
V
DDO
refer to the supply voltages on the input and output sides of the given channel, respectively.

ADUM4402CRWZ-RL

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators 5kV RMS Quad-CH Digital
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union