MX8681
IXYS
Bit field A[2:0] controls the digital filter operation:
A[2:0] Time Constant Sample Weighting
000 No Filter 1
001 T 1/2
010 3T 1/4
011 7T 1/8
100 15T 1/16
101 31T 1/32
110 63T 1/64
111 127T 1/128
Bit field B[5:0] is the full scale adjust.
Characteristics are 0.8% step size, ±25% total range.
B[5:0] = 000000 is the lowest sensitivity (highest full scale)
B[5:0] = 111111 is the highest sensitivity
One-Time Programming:
Bit Zp, when logic 1 along with A[2:0] and B[5:0] values, programs those values into the internal non-
volatile memory.
Programming a bit to logic 1 is permanent. A bit programmed to logic 1 cannot be made to go back to
logic 0.
Always send a write command with Zp = 0 and SDI = 0 immediately after the programming command.
The actual programming pulse occurs internally at the falling edge of CS* in the command following the
command in which Zp = logic 1.
The write command can be used to preview the trim bits as long as Zp is logic 0.
Examples:
The bit field B[5:0] can be programmed while the A[2:0] bit field is "000", or vice versa. For example the
total SDI bit pattern could be 10 000 001100 0000 1. This would permanently set the B[5:0] bit field to
001100 but the filter setting could still be subsequently changed by a different write command, either in
preview or programming.
The SDI bit pattern 10 010 010000 0000 0 would set the filter time constant to 3T and the full scale field
to 010000 as a preview, without making it permanent (because bit Zp = 0).
If the sample interval T = 1 mS and A[2:0] = 001 then the effective bandwidth would be 1/(2*3.14*1e-3) =
159 Hz. For this condition, if the steady state output was 2000 counts and a step input was applied that
would drive the output to 3000 counts then the digital output response would be 2000, 2500, 2750, 2875,
2937, 2968, 2984, 2992, 2996, 2998, 2999, 2999, 3000.
MX8681 5 03/03/08
Drawing No. 0868109 www.claremicronix.com