DocID026556 Rev 2 3/11
LDP01-xxAY Characteristics
11
Table 4. Electrical characteristics (parameter)
Order code
I
RM
max. at V
RM
V
BR
at I
R
(1)
V
CL
at I
PP
10/1000 µs
R
D
(2)
10/1000
µs
V
CL
at I
PP
8/20 µs
R
D
(2)
8/20 µs
⍺
T
(3)
25 °C 175 °C min. typ. max. max. max. max.
µA V V mA V A m
Ω
VAm
Ω
10
-4
/°C
LDP01-26AY 1 100 22 24.4 26 27.0 1 36 140 64 42 1400 11 9.6
LDP01-28AY 1 100 24 26.7 28 29.5 1 40 120 88 45 1250 12 9.7
LDP01-30AY 1 100 27 28.9 30 31.9 1 40 125 65 49 1400 12 9.7
LDP01-33AY 1 100 28 31.1 33 34.3 1 43.5 110 75 56 1250 17 9.8
LDP01-35AY 1 100 30 33.3 35 36.9 1 45.5 95 91 60 1150 20 9.9
LDP01-39AY 1 100 33 36.7 39 40.5 1 51.5 85 129 66 1050 24 10
LDP01-42AY 1 100 36 40 42 44.2 1 57 77 166 71 1000 27 10
LDP01-47AY 1 100 40 44.4 47 49 1 63 65 215 76.5 950 29 10.1
LDP01-50AY 1 100 43 47.8 50 52.8 1 68 55 276 81 900 31 10.2
LDP01-56AY 1 100 48 53.3 56 58.9 1 76 48 356 90 770 40 10.3
LDP01-68AY 1 100 58 64.4 68 71.2 1 92 42 495 110 620 63 10.4
LDP01-82AY 1 100 70 77.8 82 86 1 113 35 771 135 550 89 10.5
1. Pulse test: t
P
< 50 ms
2. To calculate maximum clamping voltage at other surge level, use the following formula: V
CL
max = R
D
x I
PP
+ V
BR
max
3. To calculate V
BR
or V
CL
versus junction temperature, use the following formulas:
V
BR
at T
j
= V
BR
at 25 °C x (1 +
⍺
T x (T
j
- 25))
V
CL
at T
j
= V
CL
at 25 °C x (1 +
⍺
T x (T
j
- 25))
Figure 3. Peak pulse power dissipation versus
initial junction temperature (LDP01-30AY)
Figure 4. Peak pulse power versus exponential
pulse duration (LDP01-30AY)
0
1
2
3
4
5
6
0 25 50 75 100 125 150 175 200
P
PP
(kW)
T
j
(°C )
10/1000 µs
T
J initial
= 25C
LDP01-30AY
0.1
1
10
100
1000
0.01 0.1 1 10 100
P
PP
(kW)
t
p
(ms)
T
J initial
= 25 °C
LDP01-30AY