ADuM6020/ADuM6028 Data Sheet
Rev. 0 | Page 4 of 18
ELECTRICAL CHARACTERISTICS5 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY
All typical specifications are at T
A
= 25°C, V
DDP
= 5.0 V, V
ISO
= 3.3 V. Minimum/maximum specifications apply over the entire
recommended operation range, which is 4.5 V ≤ V
DDP
≤ 5.5 V, 3.0 V ≤ V
ISO
3.6 V, and 40°C T
A
+125°C, unless otherwise noted.
Table 3. ADuM6020 DC-to-DC Converter Static Specifications
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint V
ISO
3.135 3.3 3.465 V I
ISO
= 10 mA
Line Regulation V
ISO (LINE)
2 mV/V I
ISO
= 50 mA, V
DDP
= 3.0 V to 3.6 V
Load Regulation
1
V
ISO (LOAD)
1 5 % I
ISO
= 10 mA to 90 mA
Output Ripple
1
V
ISO (RIP)
50 mV p-p 20 MHz bandwidth, C
BO
= 0.1 µF||10 µF, I
ISO
= 90 mA
Output Noise
1
V
ISO (NOISE)
130 mV p-p C
BO
= 0.1 µF||10 µF, I
ISO
= 90 mA
Switching Frequency f
OSC
180 MHz
PWM Frequency f
PWM
625 kHz
Output Supply Current
1
I
ISO (MAX)
50 mA 3.135 V < V
ISO
< 3.465 V
100 mA 3.0 V < V
ISO
< 3.465 V
Efficiency at I
ISO (MAX)
1
27
%
I
ISO
= 100 mA
V
DDP
Supply Current
No V
ISO
Load I
DDP (Q)
5 18 mA
Full V
ISO
Load I
DDP (MAX)
250 mA
Thermal Shutdown
Shutdown Temperature 154 °C
Thermal Hysteresis 10 °C
1
Maximum V
ISO
output current is derated by 1.75 mA/ºC for T
A
> 85ºC.
Table 4. ADuM6028 DC-to-DC Converter Static Specifications
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint V
ISO
3.135 3.3 3.465 V I
ISO
= 10 mA
Line Regulation V
ISO (LINE)
2 mV/V I
ISO
= 30 mA, V
DDP
= 3.0 V to 3.6 V
Load Regulation
1
V
ISO (LOAD)
1 5 % I
ISO
= 10 mA to 54 mA
Output Ripple
1
V
ISO (RIP)
50 mV p-p 20 MHz bandwidth, C
BO
= 0.1 µF||10 µF, I
ISO
= 54 mA
Output Noise
1
V
ISO (NOISE)
130 mV p-p C
BO
= 0.1 µF||10 µF, I
ISO
= 54 mA
Switching Frequency f
OSC
180 MHz
PWM Frequency f
PWM
625 kHz
Output Supply Current
1
ISO (MAX)
60
mA
3.135 V < V
ISO
< 3.465 V
Efficiency at I
ISO (MAX)
1
27 % I
ISO
= 60 mA
V
DDP
Supply Current
No V
ISO
Load I
DDP (Q)
5 18 mA
Full V
ISO
Load I
DDP (MAX)
250 mA
Thermal Shutdown
Shutdown Temperature 154 °C
Thermal Hysteresis 10 °C
1
Maximum V
ISO
output current is derated by 1 mA/ºC for T
A
> 85ºC.
Data Sheet ADuM6020/ADuM6028
Rev. 0 | Page 5 of 18
REGULATORY APPROVALS
Table 5.
UL (Pending)
1
CSA (Pending) VDE (Pending)
2
CQC (Pending)
Recognized Under 1577
Component Recognition
Program
1
Approved under CSA Component
Acceptance Notice 5A
DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Certified under
CQC11-471543-2012
Single Protection, 5000 V rms
Isolation Voltage
CSA 60950-1-07+A1+A2 and
IEC 60950-1, second edition, +A1+A2
Reinforced insulation 565 V peak,
surge isolation voltage (V
IOSM
) =
6000 V peak
GB4943.1-2011:
Basic insulation at
780 V rms (1103 V peak)
Basic insulation at 780 V rms (1103 V peak) Transient voltage (V
IOTM
) =
7070 V peak
Reinforced insulation at
390 V rms (552 V peak)
Reinforced insulation at 390 V rms
(552 V peak)
IEC 60601-1 Edition 3.1:
Basic insulation (1 means of patient
protection (1 MOPP)), 585 V rms
(827 V peak)
Reinforced insulation (2 MOPP),
238 V rms (325 V peak)
CSA 61010-1-12 and IEC 61010-1 third
edition
Basic insulation at 300 V rms mains,
780 V secondary (1103 V peak)
Reinforced insulation at 300 V rms
mains, 390 V secondary (552 V peak)
File E214100 File 205078 File 2471900-4880-0001 File (pending)
1
In accordance with UL 1577, each ADuM6020 and ADuM6028 are proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10, each ADuM6020 and ADuM6028 are proof tested by applying an insulation test voltage 1059 V peak for 1 sec (partial
discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
For additional information, see www.analog.com/icouplersafety.
Table 6. ADuM6020 Insulation and Safety
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L (I01) 8.3 mm min Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L (I02) 8.3 mm min Measured from input terminals to output terminals,
shortest distance path along body
Minimum Clearance in the Plane of the Printed
Circuit Board (PCB Clearance)
L (PCB) 8.3 mm min Measured from input terminals to output terminals,
shortest distance through air, line of sight, in the PCB
mounting plane
Minimum Internal Gap (Internal Clearance) 25.5 μm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >600 V DIN IEC 112/VDE 0303 Part 1
Material Group
I
Material Group (DIN VDE 0110, 1/89, Table 1)
Table 7. ADuM6028 Insulation and Safety
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L (I01) 8.3 mm min Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L (I02) 8.3 mm min Measured from input terminals to output terminals,
shortest distance path along body
Minimum Clearance in the Plane of the Printed
Circuit Board (PCB Clearance)
L (PCB) 8.3 mm min Measured from input terminals to output terminals,
shortest distance through air, line of sight, in the PCB
mounting plane
Minimum Internal Gap (Internal Clearance) 25.5 μm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >600 V DIN IEC 112/VDE 0303 Part 1
Material Group I Material Group (DIN VDE 0110, 1/89, Table 1)
ADuM6020/ADuM6028 Data Sheet
Rev. 0 | Page 6 of 18
PACKAGE CHARACTERISTICS
Table 8. ADuM6020 Package Characteristics
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
R
I-O
10
13
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction to Ambient Thermal
Resistance
θ
JA
45 °C/W Thermocouple located at center of package
underside
3
1
This device is considered a 2-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
3
The value of θ
JA
is based on devices mounted on a JEDEC JESD-51 standard 2s2p board and still air.
Table 9. ADuM6028 Package Characteristics
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
R
I-O
10
13
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction to Ambient Thermal
Resistance
θ
JA
80 °C/W Thermocouple located at center of package
underside
3
1
This device is considered a 2-terminal device: Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together.
2
Input capacitance is from any input data pin to ground.
3
The value of θ
JA
is based on devices mounted on a JEDEC JESD-51 standard 2s2p board and still air.
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
the protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 10. ADuM6020 VDE Characteristics
Description Test Conditions/Comments Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 150 V rms I to IV
For Rated Mains Voltage 300 V rms I to III
For Rated Mains Voltage 400 V rms I to II
Climatic Classification 40/125/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage
V
IORM
565
V peak
Input to Output Test Voltage, Method b1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1059 V peak
Input to Output Test Voltage, Method a V
PR
After Environmental Tests Subgroup 1 V
IORM
× 1.5 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
V
pd(m)
848 V peak
After Input or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
V
pd(m)
678
V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 sec V
IOTM
7070 V peak
Withstand Isolation Voltage 1 minute withstand rating V
ISO
5000 V rms
Surge Isolation Voltage Reinforced V
IOSM(TEST)
= 10 kV; 1.2 µs rise time; 50 µs, 50% fall time V
IOSM
6000 V peak
Safety Limiting Values Maximum value allowed in the event of a failure
(see Figure 3)
Case Temperature T
S
150 °C
Total Power Dissipation at 25°C I
S1
2.78 W
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9

ADUM6020-5BRIZ

Mfr. #:
Manufacturer:
Analog Devices / Linear Technology
Description:
Switching Voltage Regulators isoPower 5kV,
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union