QUINT POWER provides:
Preventive function monitoring
through
professional signaling
Global use
due to a wide range input
A high level of operational safety
even in complex
global networks
Reliable startup of heavy loads
due to
POWER BOOST
The reliability of a power supply determines the
availability of individual components in a system and
whether complex systems can function safely.
The globalization of markets increases the demands
placed on the power supply. A wide range input and a
high level of availability are required.
These requirements are met by Generation 2
QUINT POWER.
1. Short Description
QUINT POWER is the universal 24 V supply of 60 -
960 W. Output currents of 2.5, 5, 10, 20, 30, and 40 A
are available at an adjustable and regulated output
voltage of 22.5 - 28.5 V DC. Output currents of 5 A and
10 A are available for use in potentially explosive areas
of zone 2.
These devices, which are designed as primary
switched-mode regulators, operate with a high level of
efciency so that heat loss is kept to a minimum.
The high level of operational safety is also ensured in
complex global networks. QUINT POWER also
operates in applications where static voltage dips,
transient power supply failures or phase failure are
common.
Large capacitors ensure mains buffering of more
than 20 ms at full load. All 3-phase QUINT POWER
units provide the complete output power even in the
event of a continuous phase failure.
Reliable startup of heavy loads is ensured by a
power reserve of up to 50% - the POWER BOOST.
Preventive function monitoring diagnoses an
impermissible operating state and minimizes
downtimes in your system. An active transistor output
and an electrically isolated relay contact are provided
for remote monitoring of this state.
This signal not only provides information on the
device function, but also indicates a system overload at
an early stage.
1-Phase Power Supply, Primary Switch Mode
for Use in Potentially Explosive Areas
QUINT-PS-100-240AC/24DC/5/EX
Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
Local Contact: www.phoenixcontact.com/salesnetwork
2. Area of Application
The power supply corresponds to the EN 50021
standard and may be installed within a potentially
explosive area, in which Category 3 equipment is
required.
The power supply is suitable for use in Class I,
Division 2, Groups A, B, C, and D.
QUINT POWER can be used globally due to the
consistent provision of a wide range input.
In this way, your entire system can be tested at any
production location in the world and can be delivered to
any location in the world without faulty switching of the
input voltage. This reduces storage costs and logistical
effort.
An international approval package including
CB Scheme, UL 60950 for IT equipment, and UL 508
for industrial control equipment enables the device to
be used globally.
Safe operation in adverse conditions is emphasized
by the approval of the entire product range by
Germanischer Lloyd.
PHOENIX CONTACT page 2 of 10
solid exible torque
[mm
2
]AWG [Nm] [Ib in.]
Input 0.2 - 2.5 0.2 - 2.5 25 - 14 0.5 - 0.6 4.4 - 5.3
Output 0.2 - 2.5 0.2 - 2.5 25 - 14 0.5 - 0.6 4.4 - 5.3
Signal 0.2 - 2.5 0.2 - 2.5 25 - 14 0.5 - 0.6 4.4 - 5.3
Description
Power Supply
Primary switch mode for potentially explosive areas
Technical Data
Input Data
1
Nominal input voltage
Input voltage range
Frequency
Current consumption (for nominal values)
Inrush current limiting/I
2
t (+25°C [+77°F])
Mains buffering for a nominal load (typical)
Switch-on time after applying the mains voltage
Transient surge voltage protection
Input fuse, internal
Recommended fuse
Discharge current for PE
Output Data
2
Nominal output voltage U
N
/tolerance
Setting range for the output voltage
Output current during convection cooling and nominal
values POWER BOOST I
BOOST
-25°C to +40°C (-13°F to +104°F)
Nominal output current I
N
-25°C to +60°C (-13°F to +140°F)
Short-circuit current limit
Startup of capacitive loads
System deviation on: Load change static 10 - 90%
Load change dynamic 10 - 90%
Input voltage change ±10%
Maximum power dissipation No load/nominal load
Efciency
Response time U
OUT
(10% - 90%)
Residual ripple/switching peaks (20 MHz)
Can be connected in parallel
Internal surge voltage protection
Resistance to return supply
Signal Output Data
DC OK (active)
3
(U
out
> 0.9 x U
N
=
high signal)
DC OK (electrically isolated)
4
(U
out
> 0.9 x U
N
=
contact closed)
LED
6
(U
out
< 0.9 x U
N
=
LED ashing)
QUINT 24 V DC/5 A /EX
1 AC
U u F B
Type Order No.
Pcs.
Pkt.
QUINT-PS-100-240AC/24DC/5/EX 29 38 85 3
1
100 - 240 V AC (wide range input)
85 - 264 V AC 90 - 250 V DC
45 - 65 Hz 0 Hz
1.9 A (120 V AC)/0.8 A (230 V AC), approximately
20 A, approximately/2.5 A
2
s, approximately
> 20 ms (120 V AC)/> 100 ms (230 V AC)
< 1 s
Varistor
5 AT (device protection)
Circuit breaker 6 A, 10 A or 16 A
Characteristic B (EN 60 898)
< 3.5 mA
24 V DC ±1%
22.5 - 28.5 V DC
7.5 A (U
out
= 24 V DC)
5.0 A (U
out
= 24 V DC)
I
BOOST
7.5 A, approximately
Unlimited
< 1%, typical
< 2%, typical
< 0.1%, typical
2.7 W/18 W, approximately
> 87% (for 230 V AC and nominal values)
< 2 ms, typical
< 100 mV
pp
(for nominal values)
To increase redundancy and power
Ye s, limited to 35 V DC, approximately
35 V DC
+24 V DC signal (with regard to the device weight)
40 mA, maximum
30 V AC/DC, maximum; 1 A, maximum, ohmic load
Green LED
CB
Scheme
130 mm
(5.118 in.)
55 mm
(2.165 in.)
125 mm
(4.921 in.)
PE
13
14
DC OK
L (+)
N (–)
1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas –
QUINT 24 V DC/5 A/EX
3. Technical Data
7
PHOENIX CONTACT page 3 of 10
1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas –
QUINT 24 V DC/5 A/EX
General Data
Insulation voltage: Input/output
Input/PE
Output/PE
Approval package
Electrical equipment of machines
Safety transformers for switched-mode power supply units
Electrical safety
(of IT equipment)
Industrial control equipment
Shipbuilding
Equipping high voltage installations
with electronic equipment
Safety extra-low voltage
Safe isolation
Protection against electric shock
Protection against dangerous shock currents,
basic requirements for safe isolation
in electrical equipment
Limitation of harmonic line currents
Conformance mark according to EN 50021
Electrical equipment for explosion-protected areas
Mounting position
Can be mounted with spacing
Degree of protection
Class of protection
MTBF
Housing version
Dimensions (W x H x D) + DIN rail
Weight
Climatic Data
Ambient temperature Operation
Storage
Humidity
Vibration according to IEC 68-2-6
Shock according to IEC 68-2-27
Degree of pollution
Climatic category
cc
cc
Conforms to the EMC Directive 89/336/EEC and the
Low Voltage Directive 73/23/EEC
EMC (Electromagnetic Compatibility)
Noise Immunity According to EN 61000-6-2:
Electrostatic discharge
(ESD)
EN 61000-4-2
3)
Housing
Contact discharge:
Air discharge:
Electromagnetic
HF eld
EN 61000-4-3
2)
Housing
Frequency:
Field strength:
Fast transients
(burst)
EN 61000-4-4
3)
Input:
Output:
Signal:
Surge current loads EN 61000-4-5
3)
Input:
Output:
Signal:
Conducted
interference
EN 61000-4-6
2)
I/O/S:
Frequency:
U
0
:
Voltage dips EN 61000-4-11
3)
Input:
Simulation of
radiophone
EN 50204 Frequency:
Field strength:
Noise Emission According to EN 50081-2:
Radio interference EN 55011
Radio interference EN 55011
EN 55011 corresponds to CISPR11/EN 55022 corresponds to CISPR22
EN 61000 corresponds to IEC 1000
2)
Criterion A: Normal operating characteristics within the specied
limits.
3)
Criterion B: Temporary adverse effects on the operating
characteristics that the device corrects independently.
4 kV AC (type test)/2 kV AC (routine test)
3.5 kV AC (type test)/2 kV AC (routine test)
707 V DC (routine test)
BB
BB
EN 60 204 (Surge Voltage Category III)
EN 61 558-2-17
EN 60950/VDE 0805,
UL/C-UL Recognized UL 60 950
u
UL/C-UL Listed UL 508
Germanischer Lloyd
F
EN 50 178 (VDE 0160)
PELV (EN 60 204)
SELV (EN 60 950)
VDE 0100-410
DIN 57100-410
DIN VDE 0106-101
According to EN 61000-3-2
X
II 3G EEx nAC IIC T4 TÜV 03 ATEX 2047X
UL/c-UL Recognized UL 1604 Class I, Division 2, Groups A, B, C, D
On horizontal NS 35 DIN rail according to EN 50022
Vertical with
5 cm (1.969 in.)/horizontal 0 cm
IP 20
Ι
, with PE connection
> 500 000 h according to IEC 1709 (SN 29 500)
AluNox (AlMg1), closed
Default upon delivery: Rotated 90°:
(55 x 130 x 125 mm( 122 x 130 x 58 mm
[2.165 x 5.118 x 4.921 in.]) [4.803 x 5.118 x 2.283 in.])
1 kg, approximately
-25°C to +60°C/+40°C (-13°F to +140°F/104°F)
-40°C to +85°C (-40°F to +185°F)
Up to 100% at +25°C (+77°F), condensation permitted
< 15 Hz, amplitude ±2.5 mm/15 Hz - 150 Hz, 2.3 g, 90 minutes
30 g all space directions
2 (according to EN 50 178)
3K3 (according to EN 60 721)
Requirements
EN 61 000-6-2
QUINT-PS-100-240AC/24DC/5/
EX
4 kV
8 kV
Level 4
8 kV
15 kV
80 - 1000 MHz
10 V/m
Level 3
80 - 1000 MHz/1.4 - 2.0 GHz
10 V/m
2 kV asymmetrical
5)
2 kV asymmetrical
5)
1 kV asymmetrical
5)
4 kV (Level 4)
2 kV (Level 3)
1 kV (Level 2)
2 kV asymmetrical
5)
1 kV symmetrical
4)
0.5 kV asymmetrical
5)
0.5 kV symmetrical
4)
1 kV asymmetrical
5)
4 kV (Level 4)
2 kV (Level 4)
0.5 kV (Level 1)
0.5 kV (Level 1)
1 kV (Level 2)
asymmetrical
5)
0.15 - 80 MHz
10 V
Level 3
0.15 - 80 MHz
10 V
30% reduction of the input voltage
for 0.5 periods
See input data:
Mains buffering
> 20 ms
Not required 900 MHz/1800 MHz
20 V/m
Class A
6)
EN 55011 (EN 55022) Class B
7)
Class A
6)
EN 55011 (EN 55022) Class B
7)
4)
symmetrical: Cable to cable
5)
asymmetrical: Cable to ground
6)
Class A: Industrial application
7)
Class B: Industrial and domestic applications
U
LISTED

2938853

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
DIN Rail Power Supplies QUINT 24VOLT 5AMP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet