TN
SPECIFICATIONS
SLIM POLARIZED RELAY
TN RELAYS
5.6
.220
14
.551
9.8
.386
mm inch
RoHS Directive compatibility information
http://www.nais-e.com/
FEATURES
• Small header area makes higher
density mounting possible
• High sensitivity: 140 mW nominal
operating power (single side stable
3-12 V type)
• Surge voltage withstand: 1500 V FCC
Part 68
• Self-clinching terminal also available
Contact
Note:
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA
max. level])
Characteristics
Arrangement 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
60 mΩ
Contact material Gold-clad silver
Rating
Nominal switching capacity
(resistive load)
1 A 30 V DC,
0.5 A 125 V AC
Max. switching power
(resistive load)
30 W, 62.5 VA
Max. switching voltage 110 V DC,125 V AC
Max. switching current 1 A
Min. switching capacity
(Reference value)
#1
10 µA 10 mV DC
Nominal
operating
power
Single side stable
140 mW (3 to 12 V DC)
200 mW (24 V DC)
300 mW (48 V DC)
1 coil latching
100 mW (3 to 12 V DC)
150 mW (24 V DC)
2 coil latching
200 mW (3 to 12 V DC)
300 mW (24 V DC)
Expected
life (min.
operations)
Mechanical (at 180 cpm) 10
8
Electrical
(at 20 cpm)
1 A 30 V DC
resistive load
2 × 10
5
0.5 A 125 V AC
resistive load
10
5
Initial insulation resistance*
1
Min. 1,000 MΩ (at 500 V DC)
Initial
breakdown
voltage
Between open
contacts
750 Vrms for 1 min.
(Detection current: 10 mA)
Between contact and
coil
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact sets
1,000 Vrms for 1 min.
(Detection current: 10 mA)
FCC surge voltage between open
contacts
1,500 V
Temperature rise*
2
(at 20°C) Max. 50°C
Operate time [Set time]*
3
(at 20°C) Max. 3 ms [Max. 3 ms]
Release time [Reset time]*
4
(at 20°C)
Max. 3 ms [Max. 3 ms]
Shock resistance
Functional*
5
Min. 490 m/s
2
{50G}
Destructive*
6
Min. 980 m/s
2
{100G}
Vibration resistance
Functional*
7
176.4 m/s
2
{18G}, 10 to 55 Hz
at double amplitude of 3 mm
Destructive
294 m/s
2
{30G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for
operation, transport
and storage*
8
(Not freezing and
condensing at low
temperature)
Ambient
temperature
–40°C to +70°C
–40°F to +158°F
Humidity 5 to 85% R.H.
Unit weight Approx. 1.5 g .053 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µs.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10 µs.
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT .
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.