L9466 Electrical specifications
7/11
Table 6. Diagnostic (T
case
= -35°C to +150°C unless otherwise specified)
Symbol Parameter Conditions Min. Typ. Max. Units
V
OV
Over-voltage V
SP
+ 1
V
SP
+
1.3
V
SP
+ 2 V
V
UV
Under-voltage F
P
> F
P-LRC
0.95 1.8 V
V
L-SAT
Lamp ON saturation voltage I
L
= 0.5A (sinked by ASVR) >V
L-ACT
1.33 1.45 V
V
L-SAT-BO
Lamp ON voltage
(1)
I
L
< 0.5A, VGO = Open; T
case
=
-35C to 85C
3.8 5 V
V
L-RLY
Lamp OFF (relay drive)
saturation voltage (vs. B+)
I
L
= 750mA (Sourced by ASVR)
(2)
T
case
< 125°C
1.85 V
T
DELAY
Fault indication delay time Delay before Lamp ON 0.9 1.1 1.3 s
1. This condition can happen when the connection between the battery and VGO or the output terminal of the generator is
broken. The 1.1 second delay is not required, and current is sinked by ASVR.
2. When no fault is detected the Lamp terminal is pulled up by ASVR.
Table 7. Fault indication table
Conditions T
Delay
Initial KEY-ON Bulb and Wiring Check (Lamp ON for 1 sec. 15% after initial KEY-ON) No
V
GO
> V
OV
Ye s
V
P
< V
P-F
AND V
GO
< V
SP
Ye s
F
P
< F
P-TR
@ V
P-TR
Ye s
No Connection Between Battery and V
GO
No
At Start: Lamp ON until F
P
>F
P-IR
AND V
P
>V
P-F
. i.e. until V
P
reaches 8V. No
Table 8.
Regulation features
Symbol Parameter Conditions Min. Typ. Max. Unit
V
L-PD
L terminal regulator activate
threshold
VGO=12.6V 0.8 1 1.15 V
I
L-PD
L terminal pull down current
V
L
= V
L-ACT
VGO=12.6V
0.09 0.78 mA
V
P-IR
Initiate regulation phase voltage
threshold
Regulator Activated 1.1 1.3 1.5 V
I
P
Phase terminal current sink
V
P
> 1.5V and < 12.6V
VGO = 12.6V
0.25 3.5 mA
F
P-IR
Initiate regulation phase
frequency
123 145 167 Hz
F
P-TR
Terminate regulation phase
frequency
59 72 86 Hz
IRD Initiate regulation delay
Regulator activated, V
P-IR
and
F
P-IR
Conditions Met First Time.
1.722.3s
Electrical specifications L9466
8/11
FSDC Field strobe duty cycle
Regulator activated AND
(regulation terminated OR
regulation NOT initiated)
16 18.75 22 %
LRC Load response control rate Field drive duty cycle increase 8.5 10 11.5 %/s
F
P-LRC
LRC transition frequency LRC enabled if F
P
< F
P-LRC
255 300 345 Hz
SS Soft-start
LRC enabled until V
SP
reached
regardless other conditions
34 40 46 %/s
Table 8.
Regulation features
(continued)
Symbol Parameter Conditions Min. Typ. Max. Unit
L9466 Package information
9/11
4 Package information
In order to meet environmental requirements, ST (also) offers these devices in ECOPACK
®
packages. ECOPACK
®
packages are lead-free. The category of second Level Interconnect
is marked on the package and on the inner box label, in compliance with JEDEC Standard
JESD97. The maximum ratings related to soldering conditions are also marked on the inner
box label.
ECOPACK is an ST trademark. ECOPACK specifications are available at: www.st.com.
Figure 4. Multiwatt8 mechanical data and package dimensions
OUTLINE AND
MECHANICAL DATA
0043696 F
DIM.
mm inch
MIN. TYP. MAX. MIN. TYP. MAX.
A50.197
B 2.65 0.104
C1.60.063
E 0.49 0.55 0.019 0.022
F 0.78 0.85 0.030 0.033
G 2.40 2.54 2.68 0.094 0.10 0.105
G1 17.64 17.78 17.92 0.69 0.70 0.71
H1 19.6 0.772
H2 20.2 0.795
L 20.35 20.65 0.80 0.81
L2 17.05 17.20 17.35 0.67 0.68 0.68
L3 17.25 17.5 17.75 0.679 0.689 0.699
L4 10.3 10.7 10.9 0.406 0.421 0.429
L7 2.65 2.9 0.104 0.114
S 1.9 2.6 0.075 0.102
S1 1.9 2.6 0.075 0.102
U 0.40 0.55 0.015 0.022
Z 0.70 0.85 0.028 0.034
Dia1 3.65 3.85 0.144 0.152
Multiwatt8 (Pin 5 GND)

L9466N

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Linear Voltage Regulators Car Alternator Voltage Regulator