8-1437449-6

Figure 1 (cont’d)
Instruction Sheet
408--8452
LOC B
1 of 2
E2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
TE logo is a trademark.
*Trademark. Other product names, logos, or company names might be trademarks of their respective owners.
TOOLING ASSI STANCE CENTER 1--800--722--1111
PRODUCT INFORMATION 1--800--522--6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com
14 MAR 11 Rev A7000 Series 4- Pole Timing Relay
1. INTRODUCTION
This instruction sheet covers the installation and
operation of the AGASTAT* 7000 Series 4--Pole
T iming Relays (Models 7014 and 7024). Read these
instructions thoroughly before installing the relay.
Dimensions in this instruction sheet are in
millimeters [with inches in brackets]. Figures are
not drawn to scale.
2. DESCRIPTION (Figure 1)
Each relay is a precise timing instrument which
balances pneumatic, electrical, and mechanical forces
using a minimum of moving parts. When satisfactory
performance cannot be restored, the unit should be
returned to TE Connectivity for repair .
Model 7014
L1
Coil
Energized
De--Energized
Closed
Open
Closed
Open
N.O. (1--5)(2--6)
Contacts
L2
5
1
3
4
2
6
TD
on
Pick--
Up
Closed
Open
Closed
Open
Contacts
N.C. (9--11)(10--12)
N.C. (3--5)(4--6)
N.O. (7--11)(8--12)
7
11 10 12
9
4--Pole Timing Relay
(Typ)
Delay Setting
8
L1
L2
5
1
3
4
2
6
TD
on
Drop--
Out
7
11 10
129
Delay Setting
8
Coil
Energized
De--Energized
Closed
Open
N.C. (1--5)(2--6)
Contacts
N.O. (9--11)(10--12)
N.O. (3--5)(4--6)
N.C. (7--11)(8--12)
Closed
Open
Closed
Open
Closed
Open
Contacts
Model 7024
LINEAR TIMING RANGES
TIME RANGE
CODE
MODEL 7014D
MODEL 7024
A 0.2 to 2 Seconds 0.1 to 1 Second
B 0.7 to 7 Seconds 0.5 to 5 Seconds
C 2 to 20 Seconds 1.5 to 15 Seconds
D 10 to 100 Seconds 5 to 50 Seconds
E 30 to 300 Seconds 20 to 200 Seconds
F 1.5 to 15 Minutes 1to10Minutes
H 3to30Minutes 3to30Minutes
I Not Available 6to60Minutes
J Not Available 3 to 120 Cycles
K Not Available 1 to 300 Cycles
D Model 7014 is available with letter calibrated dials only . The upper
end of the time ranges in this model may be twice the values shown.
NOTE
408- 8452
Rev A2 of 2
AC COIL UNITS DC COIL UNITS
CODE
LETTER
RATED
VOLTAGE
AT 60 Hz
RATED
VOLTAGE
AT 50 Hz
CODE
LETTER
RATED
VOLTAGE
A 120 110 M 28
B 240 220 N 48
C 480 -- O 24
D 550 -- P 120
E 24 -- Q 12
F -- 127 R 60
G -- 240 S 250
H 12 -- T 550
I 6 -- U 16
J 208 -- V 32
W 96
K
Dual Voltage Coil
(
C
o
m
b
i
n
e
s
A
a
n
d
B
)
Y 6
(
C
o
m
b
i
n
e
s
A
a
n
d
B
)
Z 220
AC Specials L1, L2, etc. DC Specials X1, X2, etc.
Operational voltage range 90% to 120% for AC units: 85% to 120%
for DC units.
All units draw approximately 8 watts power at rated voltage.
Minimum operating voltages are based on vertically mounted Model
7014 (on--delay) units.
AC units drop out at approximately 50% of rated voltage. DC units
drop out at approximately 40% of rated voltage.
All units may be operated on intermittent duty cycle at voltages 10%
above the listed maximums. (Intermittent duty -- maximum 50% duty
cycle and 30 minutes “on time.)
Coils are rated 6 V ac through 550 Vac.
CONTACT RATINGS
(Contact Capacity in Amperes -- Resistive Loads)
CONTACT
VOLTAGE
MINIMUM 100,000
OPERATIONS
MINIMUM 1,000,000
OPERATIONS
30 Vdc 15.0 7.0
110 Vdc 1.0 0.5
120 Vac 60 Hz 20.0 15.0
240 Vac 60 Hz 20.0 15.0
480 Vac 60 Hz 12.0 10.0
Inductive and capacitive loads should not have inrush currents that
exceed five times normal operating load.
Contact ratings are listed under the Underwriters Laboratories Inc.
Component Recognition Program for 100,000 operations:
10 A Resistive, 240 V ac (per pole)
1/4 Horsepower, 120 Vac/240V ac (per pole)
15 A, 30 Vdc (per pole)
5 A, General Purpose, 600 Vac
Total load must not exceed twice the above listings per pole rating.
Continuous duty rating is 25 amperes any voltage, any load.
Figure 1 (end)
3. MOUNTING INSTRUCTIONS (Figure 2)
Normal mounting of the relay is in a vertical position,
from the back of the panel. Four No. 8--32 tapped
holes are provided in the back plate.
Mounting screws should not project more than
3.63 mm [5/32 in.] into the back of the unit, to
prevent internal damage.
A bracket and required screws are supplied with each
unit for mounting the unit from the front. The bracket
extends approximately 9.52 mm [3/8 in.] from each
side of the unit.
Horizontal operation is not recommended.
Figure 2
9.6 [.38]
12.7
[.50]
147.8
[5.82]
Max.
84.3
[3.32]
Max.
8--32 Mtg
Holes (4)
Models 7014 and 7024 (Mounting Dimensions)
38.1
[1.50]
63.5
[2.50]
65.3
[2.57]
Max.
5.1 [.199] Dia
Mtg Holes
76.2
[3.00]
82.5 [3.25]
73.2 [2.88]
19.0
[.75]
44.4
[1.75]
4. QUALIFICATIONS
The 7000 Series T iming Relays are Listed by
Underwriters Laboratories Inc. (UL) in File E15631.
and Certified to CSA International in File LR29186.
5. REVISION SUMMARY
S Updated document to corporate requirements
S New logo
CAUTION
NOTE

8-1437449-6

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Time Delay & Timing Relays 7014ADL=RLY,STD,ON,4P,120VAC,
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union