Electrical specification L9911
16/20 DocID10990 Rev 13
Note: The diagnostic result is disabled during the Soft-start delay time t_ST 0...3 and the soft-start
/ soft attack timing t_SL 0...3
Figure 14. DF monitor electrical configuration
Figure 15. Short circuit drivers' protection
Field driver, DFMon driver and Relay driver are protected in switching mode (not linear),
with a retry time less than 25 ms.
Lamp driver is protected in linear mode, with a retry time of 1 s.
Table 10. Fault detection
Root cause Signal Effect Test detect
Alternator belt breaking P Alternator disexcitation VP<VPHH1 & VB+<Vreg
Brushes open P Alternator disexcitation VP<VPHH1 & VB+<Vreg
Field driver open P Alternator disexcitation VP<VPHH1 & VB+<Vreg
Field interruption P Alternator disexcitation VP<VPHH1 & VB+<Vreg
Field short circuit to the battery F+ Overvoltage VF+>VS1 & VB+ > Vov-d
Field short circuit to the ground P Alternator disexcitation VP<VPHH1 & VB+<Vreg
Battery discharge B+ Undervoltage VB+<Vuv
,