MLX75303
Optical Switch SensorEyeC
390107530301 Page 9 of 12 Data Sheet
Rev. 001 Feb/09
Functional check of E
eon
and E
eoff
thresholds and timing measurements (Go-NoGo tests):
8 Applications Information
A typical connection diagram is shown in the figure below. A load resistor R
L
is needed to get a voltage level
out. The load capacitance C
L
is typically formed by the input capacitance of the component that is connected
to the sensor output, the wiring capacitance and the output capacitance of the sensor itself.
Decoupling capacitors between Vdd and Vss (1uF in parallel with 100nF) are highly recommended in all
configurations.
Recommendation: every change in the application should be agreed by both parties.