H7BR
H7BR
23
Precautions
Sensor Power Supply
• The capacity of the external power supply is 160 mA at 12
VDC/80 mA at 24 VDC switchable. When using a 24 VAC/12 to
24 VDC power supply type H7BR, reduce the load with the
power supply voltage, as shown in the following diagram (When
supplying external power).
Supply voltage (VDC)
12 VDC
24 VDC
160
80
20
10
0
1710 20 25
Load current (mA)
Power Supplies
• When turning the power ON and OFF, input signal reception is
possible, unstable, or impossible as shown in the diagram below.
The unstable period will vary with power supply voltage, and the
load conditions on external power supplies.
ON
OFF
0 to 50 ms
10 ms
0 to 1.2 s
Power
supply
Input impossible impossible
Possible
Unstable
• A switching regulator is used in the internal circuits of counters
with 100-to-240-VAC or 12-to-24-VAC specifications, causing
an inrush current (approx. 1.5 A) to flow when power is turned on.
If the capacity of the power supply to the counter is insufficient,
the counter may not start operation. Be sure to provide adequate
capacity (recommended supply capacity; 25 W min.)
• Connect the power supply voltage through a relay or switch in
such a way that the voltage reaches a fixed value immediately.
DIP Switch Setting Changes
Any changes in the DIP switch settings while power is being sup-
plied is invalid. Restart the power supply.
Self-diagnostic Function
• The following displays will appear if an error occurs. The present
value and output enter the same status as after pressing the
RESET Key.
Display
Error Output
status
Correction Function
setting
ĆĆĆĆĆĆ*
Present
value
below min.
No
change
Press
RESET Key
No
change
ffffff**
Present
value
above max.
or reset
input
e1
CPU OFF Press
RESET Key
e2
Memory Set at the
factory
*Displayed when the present value has fallen below the min. value
in the H7BR-C (±range type).
**Displayed when the present value has exceeded the max. value in
the H7BR-C (±range type).
Operating Environment
• When using the Counter in an area with much electronic noise,
separate the Timer, wiring, and the equipment which generates
the input signals as far as possible from the noise sources. It is
also recommended to shield the input signal wiring to prevent
electronic interference.
• Organic solvents (such as paint thinner), as well as very acidic or
basic solutions might damage the outer casing of the Counter.
Using the Prescale Function
• When setting the prescale value, be sure that the set value
satisfies this equation: set value “max. value - prescale value’. (if
the prescale value is 1,250, 999.999 - 1,250 = 998.749 max.)
• If a higher value is used, the output may be affected, so make
sure that the output is produced before starting operation.
Changing Set Values
• When changing the set value while the Counter is operating, the
output will be produced if the set value ever equals the present
value. To avoid triggering the output, begin by incrementing a
higher digit to a large number.
Resetting with a Set Value of 0
• When resetting is performed with the set value set to “0,” no
output will be given for the safety reasons once the reset is
turned OFF (except for the H7BR-C).