One-shot output from Output 1
Self-holding output Self-holding output
One-shot output from Output 2
One-shot outputs can be set to between 10 and 1,000 ms.
Batch Counter Operation
The batch counter counts the number of times set value is reached for 1-stage models, and the number of times set 2 is reached for 2-stage
models.
Batch count reset
Batch output
Batch count set
value
Batch count present
value 0
The batch count output holds until
reset by the batch count reset.
The present value of the batch count
advances continuously.
1. The batch count present value remains at 0 while the batch
count reset is ON.
2. When the batch count set value is 0, the batch count will
proceed, but there will be no output.
3. When the batch count present value exceeds 9999, it returns
to 0.
4. The batch count present value and output do not affect the
RESET Key or reset input.
5. When power is interrupted and the batch count output is ON,
the output will be ON when power returns.
6. When a batch count set value which is greater than the
present value is changed to a set value which is less than the
present value, the output will go ON.
7. If, after the output has gone ON, the set value is changed to a
set value which is greater than the present value, the output
will remain ON.
H7BR-C
Output 2 operation applies for 1-stage models only.
Output
Input mode
mode Up/Down A.B.C
K
Reset
999,999
Set 2
Set 1
0
Output 1
Output 2
Comp.
-999,999
Comp.
Present value increments and decrements within displayable range. Outputs go ON for one-shot.
D
Reset
999,999
Set 2
Set 1
0
Output 1
Output 2
Comp.
-999,999
Comp.
Present value increments and decrements within displayable range. Outputs are ON during the count is equal.