H7BR
H7BR
9
Setting Item Table
Mode Setting item
Applicable model
Description Setting procedure
(Display)
H7BR-Bj H7BR-Cj
Run
mode
Set value 1
(SET1)
Set value 2
(SET2)
Yes Yes Compared to the
present value,
determines the
timing of the control
output according to
the output mode. The
DISPLAY Key
switches between
set values 1 and 2.
(2-stage model only.)
Sequence when changing a digit using the
Keys (1 to 6).
......
08912
Press the Code Key (+/–) to change the plus or
minus sign of the set value if the model is the
H7BR-C.
(+) (blank) (-)
Ć
Batch count
set value
Yes No Batch output is
turned ON when the
set number of times
is counted.
......
08912
Sequence when changing a digit using the
Keys (1 to 6).
Function
setting
mode
Input mode
(IN)
Yes Yes Determines the input
mode selecting from
Up, Down, Up/Down
modes.
Press keys 1 to 6 to change the mode.
(Up) (Down) (Up/Down A) (Up/Down B) (Up/Down C)
*H7BR-B only.
u* d* udĆa udĆb udĆc
Output mode
(OUT)
Yes Yes Determines the form
of the control output.
(Refer to the present
value vs. output
diagrams on pages
15 to 18.)
Determines the
output time for
control output
(Output 2).
Press keys 1 to 6 to change the mode.
H7BR-B
H7BR-C
(N) (F) (C) (R) (K) (P) (Q) (A)
(K) (D) (L) (H)
*
2-stage model only.
Press keys 1 to 6 to change the Output 2 time. (Applica-
ble to output modes C, R, K, P, Q, and A only.
nf cR p Q aK
Kdl h*
*
10ms 50ms 100ms 200ms
500ms
1000ms
Output time
1 (2-stage
model only)
(OUT)
Yes Yes Determines the
output time of the
control output (OUT
1) for 2-stage model
counters.
Press keys 1 to 6 to change the set value.
*H7BR-BW only.
*
10ms 50ms 100ms 200ms
hold (self holding)
500ms
1000ms
CP1 and
CP2 Count
speed
(CP1, CP2)
Yes Yes Switches the count
input filter to protect
against errant counts
due to interference.
Press keys 1 to 6 to change the set value.
(30cps) (1kcps) (5kcps) (10Kcps)
30 1K sK
•
The response speeds of the gate input and com-
pensation input are both set to the count speed of
CP1 or CP2, whichever is faster.
• The CP1 and CP2 count speed must be set to the
same value only when the H7BR is in Up/Down C
input mode.
10K
Min. reset
time
(RST)
Yes Yes Determines the initial
signal width of the
external reset.
Press keys 1 to 6 to change the set value.
(1 ms) (20 ms)
120
Decimal
point
(------)
Yes Yes Determines the
decimal point
position of the
present and set
values.
Move the decimal point position with keys, 1 to 6.