Characteristics STTH30L06-Y
2/8 Doc ID 018925 Rev 1
1 Characteristics
To evaluate the conduction losses use the following equation:
P = 0.95 x I
F(AV)
+ 0.010 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
Forward rms voltage 50 A
I
F(AV)
Average forward current T
c
= 125 °C = 0.530A
I
FSM
Surge non repetitive forward current t
p
= 10 ms sinusoidal 300 A
T
stg
Storage temperature range -65 to +175 °C
T
j
Operating junction temperature range -40 to +175 °C
Table 3. Thermal resistance
Symbol Parameter Value (max) Unit
R
th(j-c)
Junction to case 1.1 °C/W
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
R
(1)
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
25
µA
T
j
= 150 °C 80 800
V
F
(2)
Forward voltage drop
T
j
= 25 °C
I
F
= 30 A
1.55
V
T
j
= 150 °C 1.0 1.25
1. Pulse test: t
p
= 5 ms, < 2%
2. Pulse test: t
p
= 380 µs, < 2%
Table 5. Dynamic Characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
rr
Reverse recovery
time
T
j
= 25 °C
I
F
= 0.5 A, I
rr
= 0.25 A,
I
R
=1 A
65
ns
I
F
= 1 A, dI
F
/dt = 50 A/µs,
V
R
=30 V
65 90
I
RM
Reverse recovery
current
T
j
= 125 °C
I
F
= 30 A, V
R
= 400 V,
dI
F
/dt = 100 A/µs
11.5 16 A
t
fr
Forward recovery
time
T
j
= 25 °C
I
F
= 30 A, dI
F
/dt = 100 A/µs,
V
FR
= 1.1 x V
Fmax
500 ns
V
FP
Forward recovery
voltage
T
j
= 25 °C
I
F
= 30 A, dI
F
/dt = 100 A/µs,
V
FR
= 1.1 x V
Fmax
2.5 V