Technical Data Sheet
F 75 Ω
Calibration Load
Jack
74K150-C10S3
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2 / 3
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt
● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical data
Frequency range DC to 4 GHz
Return loss ≥ 40 dB, DC to 4 GHz
DC Resistance 75 Ω ± 0.75 Ω
Power handling ≤ 0.5 W
Mechanical data
Mating cycles ≥ 500
Maximum torque 6.78 Nm
Recommended torque 2.00 Nm
Accommodate male contact diameter 0.76 mm to 0.86 mm
Gauge 0.00 mm to 0.10 mm
General standard definitions
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Z
o
/ Impedance / Z
o
75 Ω
Offset Delay 0.0000 ps
Length (electrical) / Offset Length 0.00 mm
Offset Loss 0.00 GΩ/s
Loss 0.0000 dB/
GHz
Environmental data
Operating temperature range
1
+20 °C to +26 °C
Rated temperature range of use
2
0 °C to +50 °C
Storage temperature range -40 °C to +85 °C
RoHS compliant
1
Temperature range over which these specification are valid.
2
This range is underneath and above the operating temperature range, within the calibration load is fully functional