Rev. 12.17.13
DS2500PE-3
3 of 9
Embedded Power for
Business-Critical Continuity
Input Signals
PSON
Active LOW signal which enables/disables the main output. Pulling this signal LOW will turn-on the main output.
MIN MAX
V
IL
Input logic level LOW 0.8 V
V
IH
Input logic level HIGH 2.0 V 3.46 V
I
SOURCE
Current that may be sourced by this pin 2 mA
I
SINK
Current that may be sunk by this pin at low state 0.5 mA
FAN_POWER
Supplies the fan voltage to the power supply. These pins should be tied to the main 12V output at the system side.
MIN MAX
I
SINK
Current that may be sinked by this pin 3.0 A
Output Signals
ACOK
Signal used to indicate the presence of AC input to the power supply. A logic level HIGH will indicate that the AC input to the power
supply is within the operating range while a logic level LOW will indicate that AC has been lost.
MIN MAX
V
IL
Input logic level LOW 0.6 V
V
IH
Input logic level HIGH 2.0 V 3.3 V
I
SOURCE
Current that may be sourced by this pin 3.3 mA
I
SINK
Current that may be sunk by this pin at low state 0.7 mA
PWR_GOOD / PWOK
“Signal used to indicate that main output voltage is within regulation range. The PWR_GOOD signal will be driven HIGH when the output
voltage is valid and will be driven LOW when the output falls below the under-voltage threshold.
This signal also gives an advance warning when there is an impending power loss due to loss of AC input or system shutdown request.
More details in the Timing Section.
MIN MAX
V
IL
Output logic level LOW 0.8 V
V
IH
Output logic level HIGH 2.0 V 3.46 V
I
SOURCE
Current that may be sourced by this pin 3.3 mA
I
SINK
Current that may be sunk by this pin 0.7 mA
Control and Status Signals