MS05-2A87-78L

A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet MS Reed Relays
www.standexmeder.com
MS Series
Reed Relays
Features: Micro Single In-Line Relay, High Resistance Coil Option available
Applications: ATE Systems, Computer Peripherals, Alarm Systems, Measurement Equipment & Others
Markets: Test and Measurement, Security & Others
Part
Description: MS 00- 1 A 87- 75X
Nominal
Voltage
Contact
QTY
Contact
Form
Switch
Model
Pin Out Option
05, 12 1 A, 87 75
L, D
(HR = High Resistance Version)
Customer
Options
Switch Model
Unit
Contact Data
87
Rated Power
(max.)
Any
DC combination of V&A not to exceed their individual max.’s
10 W
Switching Voltage
(max.)
DC or
peak AC
200 V
Switching Current
(max.)
DC
or peak AC
0.5 A
Carry Current
(max.)
DC
or peak AC
1.0 A
Contact Resistance
(max.)
@
0.5V & 50mA
150 mOhm
Breakdown
Voltage (min.)
According
to EN60255-5
0.225 kVDC
Operating
Time (max.)
Incl. Bounce; Measured with w/ Nominal Voltage
0.5 ms
Release Time (max.)
Measured
with no Coil Excitation
0.1 ms
Insulation
Resistance (typ.)
Rh<45
%, 100V Test Voltage
10
11
GOhm
Capacitance
(typ.)
@
10kHz across open Switch
0.2 pF
Modifications in the sense of technical progress are reserved.
Version 01
27.01.2015
USA: +1.866.782.6339 salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet MS Reed Relays
www.standexmeder.com
Coil Data
Coil Voltage
(nom.)
Coil Resistance
(typ.)
Pull-In Voltage
(max.)
Drop-Out Voltage
(min.)
Nominal Coil Power
(typ.)
Contact
Form
Switch
Model
Unit VDC Ohm VDC VDC mW
1A 87
05 280 3.75 0.5 89
05HR 500 3.75 0.75 50
12 700 8.4 1.8 205
The Pull
-In / Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per °C.
MS Reed Relay
Environmental
Data Unit
50 g
Resistance (max.)
20 g
-20 to 70 °C
-35 to 95 °C
Temperature (max.)
260 °C
Life Test Data
*Load increase reduces life
expectancy of Reed Switches
Glossary
Contact Form
Form
A
NO = Normally Open Contacts
SPST = Single Pole Single
Throw
Form B
NC = Normally Closed
Contacts
SPST
= Single Pole Single Throw
Form C
Changeover
SPDT = Single Pole Double
Throw
Handling
& Assembly Instructions
Switching inductive and/or capacitive loads create voltage
and/or current peaks, which may damage the relay.
Protective circuits need to be used.
External magnetic fields needs to be taken into
consideration, including a too high packing density. This may
influence the relays’ electrical characteristics.
Mechanical shock impacts e.g. dropping the relays may cause
immediate or post-installation failure.
Wave soldering: maximum 260°/5 seconds.
Reflow soldering: Recommendations given by the soldering
paste manufacturer need to be considered as well as the
temperature limits of other components/processes.
Modifications in the sense of technical progress are reserved.
Version 01
27.01.2015
USA: +1.866.782.6339 salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet MS Reed Relays
www.standexmeder.com
Pin Out
Top View
3.81mm [0.15“] pitch grid
Pin #2 must be positive when internal diode protection is present.
Modifications in the sense of technical progress are reserved.
Version 01
27.01.2015
USA: +1.866.782.6339 salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com

MS05-2A87-78L

Mfr. #:
Manufacturer:
MEDER electronic (Standex)
Description:
Reed Relays 2 Form A DPST-NO 5V Micro SIL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet