FUNCTIONAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Conditions ➀
Minimum Typical/Nominal Maximum Units
Input Voltage, Continuous Full power operation 0 15 Vdc
Input Reverse Polarity None, install external fuse None Vdc
On/Off Remote Control Power on or off, referred to -Vin 0 14 Vdc
Output Power 0 7.5 7.65 W
Output Current Current-limited, no damage, short-circuit protected 0 1.5 A
Storage Temperature Range Vin = Zero (no power) -55 125 °C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifi cations Table is not implied or recommended.
INPUT
Operating voltage range Vin≥Vout+2V for 3.3V and 5V 4.5 12 14 Vdc
Recommended External Fuse Fast blow 3 A
Turn On/Start-up threshold Rising input voltage 3.9 4.2 4.4 Vdc
Turn Off/Undervoltage lockout Falling input voltage 3 3.4 3.7 Vdc
Reverse Polarity Protection None, install external fuse None Vdc
Internal Filter Type C-TYPE
Input current
Full Load Conditions Vin = nominal (5Vo set) 0.672 0.701 A
Low Line Vin @ min, 5 Vout 1.122 1.163 A
Inrush Transient 0.4 A
2
-Sec.
Short Circuit Input Current 60 mA
No Load Input Current 5Vout, Iout @ 0 80 100 mA
No Load Input Current 0.59V, Iout @ 0 40 55
Shut-Down Mode Input Current 5mA
Refl ected (back) ripple current
➁
Measured at input with specifi ed fi lter 20 mA, pk-pk
GENERAL and SAFETY
Effi ciency
@ Vin nom, 5Vout 91 93 %
@ Vin min, 5Vout 94 95.5 %
@ Vin nom, 3.3Vout 88.5 90 %
@ Vin nom, 2.5Vout 86 88 %
@Vin nom, 1.8Vout 82.5 84.5 %
@Vin nom, 1.5Vout 80 82.5 %
@Vin nom, 1.2Vout 77 79 %
@Vin nom, 1Vout 74 76 %
Safety
Certifi ed to UL-60950-1, IEC/EN60950-1,
2nd Edition
Yes
Calculated MTBF
➃
Per Telcordia SR332, issue 1, class 3, ground
fi xed, Tambient=+25°C
10.7 Hours x 10
6
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency 600 KHz
Startup Time
Power On to Vout regulated
(100% resistive load)
6mS
Startup Time Remote ON to 10% Vout (50% resistive load) 6 8 mS
Dynamic Load Response
50-100-50% load step, settling time to within
±2% of Vout di/dt = 2.5 A/µSec
50 100 µSec
Dynamic Load Peak Deviation same as above 100 200 mV
FEATURES and OPTIONS
Remote On/Off Control ➄
“P” suffi x: a 49.2K pulldown to ground needed.
Positive Logic, ON state Pin open=ON 2 +Vin V
Positive Logic, OFF state 0 0.2 V
Control Current open collector/drain 1 mA
15
OKR-T/1.5-W12-C
Adjustable Output 1.5-Amp SIP-mount DC/DC Converters
MDC_OKR-T/1.5-W12-C.A03 Page 3 of 16
www.murata-ps.com/support