B59095A0080B110

Please read Cautions and warnings and Page 4 of 8
Important notes at the end of this document.
Overcurrent protection for telecom
Leadless round disks
Avoid storage of thermistor in harmful environment with effect on function on long-term operation
(examples given under operation precautions).
Use thermistor within the following period after delivery:
Through-hole devices (housed and leaded PTCs): 24 months
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months
Telecom pair and quattro protectors (TPP, TQP): 24 months
Leadless PTC thermistors for pressure contacting: 12 months
Leadless PTC thermistors for soldering: 6 months
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months
SMDs in EIA sizes 0402, 0603, 0805 and 1210: 12 months
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering (where applicable)
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Standard PTC heaters are not suitable for soldering.
Mounting
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting.
Especially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of the
thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Please read Cautions and warnings and Page 5 of 8
Important notes at the end of this document.
Overcurrent protection for telecom
Leadless round disks
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Operation
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal
atmospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas,
ammonia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with
any liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage caused
by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Symbols and terms
A
Area
C
th
Heat capacity
f
Frequency
I
Current
Imax
Maximum current
I
R
Rated current
IPTC
PTC current
I
r
Residual currrent
Ir,oil
Residual currrent in oil (for level sensors)
Ir,air
Residual currrent in air (for level sensors)
IRMS
Root-mean-square value of current
I
S
Switching current
ISmax
Maximum switching current
LCT
Lower category temperature
N
Number (integer)
N
c
Operating cycles at V
max
, charging of capacitor
N
f
Switching cycles at V
max
, failure mode
P
Power
P
25
Maximum power at 25 °C
P
el
Electrical power
P
diss
Dissipation power
R
min
Minimum resistance
R
R
Rated resistance
R
R
Tolerance of R
R
Please read Cautions and warnings and Page 6 of 8
Important notes at the end of this document.
Overcurrent protection for telecom
Leadless round disks
R
P
Parallel resistance
R
PTC
PTC resistance
R
ref
Reference resistance
R
S
Series resistance
R
25
Resistance at 25 °C
R25,match
Resistance matching per reel/ packing unit at 25
°C
R
25
Tolerance of R
25
T
Temperature
t
Time
T
A
Ambient temperature
t
a
Thermal threshold time
T
C
Ferroelectric Curie temperature
t
E
Settling time (for level sensors)
T
R
Rated temperature
Tsense
Sensing temperature
T
op
Operating temperature
TPTC
PTC temperature
t
R
Response time
T
ref
Reference temperature
TRmin
Temperature at minimum resistance
t
S
Switching time
T
surf
Surface temperature
UCT
Upper category temperature
V or V
el
Voltage (with subscript only for distinction from
volume)
VRMS
Root-mean-square value of voltage
V
BD
Breakdown voltage
V
ins
Insulation test voltage
Vlink,max
Maximum link voltage
V
max
Maximum operating voltage
Vmax,dyn
Maximum dynamic (short-time) operating voltage
Vmeas
Measuring voltage
Vmeas,max
Maximum measuring voltage
V
R
Rated voltage
V
PTC
Voltage drop across a PTC thermistor
α
Temperature coefficient
Tolerance, change

B59095A0080B110

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Thermistors - PTC 95-B 80-A110 7.6X2.5 PTC Thermisto
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet