Product Data Sheet 4606 ZWU-879
07/15/2014 page 7 of 10
3.5 Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.4
a.) Operation condition:
2.650 1/min at free air flow Frequency: 50 Hz
Optimal operating point 130,0 m3/h @ 15 Pa
Sound power level at the optimal operating
point
5,1 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
37,0 dB(A)
b.) Operation condition:
3.100 1/min at free air flow Frequency: 60 Hz
Optimal operating point 148,0 m3/h @ 20 Pa
Sound power level at the optimal operating
point
5,5 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
42,0 dB(A)
Product Data Sheet 4606 ZWU-879
07/15/2014 page 8 of 10
4 Environment
4.1 General
Min. permitted ambient temperature TU min.
-40 °C / 50 Hz
-40 °C / 60 Hz
Max. permitted ambient temperature TU max.
70 °C / 50 Hz
80 °C / 60 Hz
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 100 °C
4.2 Climatic requirements*)
IP-protection type (certified) IP 55 **)
Humidity requirements humid temperature, cyclic; according to DIN EN
60068-2-38, 10 cycle and condensation water
check; according to DIN EN ISO 6270-2, 14 days
Salt fog requirements None
*) Permittet application area:
The product is for the use in partial sheltered rooms or open, roofed areas. Direct exposure to water is allowed
provided that this does not prevent the normal operation. Saline ambient conditions must be avoided.
Pollution degree 3 (according DIN EN 60664-1)
It occurs conductive pollution or dry non-conductive pollution which becomes conductive due to condensation.
**) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above
mentioned short description of the protection scope is not final. For detailed information of the respective protection
scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles)
with the letter K.
Short description of the IP-protection type:
Solid particle Protection: Protected against dust.
Protection against deliberate contact: Protected against contact to hazardous parts with a wire.
Protection against water: Protected against water jets.
Product Data Sheet 4606 ZWU-879
07/15/2014 page 9 of 10
5 Safety
5.1 Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
1000 VAC / 1 Min.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
1500 VAC / 1 Sec.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
RI > 50 MOhm
clearance / creepage distance 2,0 mm / 1,1 mm
Protection class I
5.2 Approval Tests
CE Yes
UL
Yes
/
UL507, Electric Fans
VDE
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
CSA Yes / C22.2 No. 113 Fans and Ventilators
CCC Yes / GB 12350 Safety Requirements for small Power Motors
The approval tests are observed to:
U approval max.: 115 V / f: 60 Hz @ TU approval max.: 85 °C
6 Reliability
6.1 General
Life expectancy L10 at TU = 40 °C
37.500 h / 50 Hz
Life expectancy L10 at TU max.
17.500 h / 50 Hz

4606ZWU-879

Mfr. #:
Manufacturer:
ebm-papst
Description:
AC Fans AC Tubeaxial Fan, 120x120x38mm, 115VAC, 29.5CFM, 45dBA, 3100RPM, Terminals, IP65
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union