236
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level L
p
A measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
– Possible special versions:
(See page 12)
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54
Max. 94 m
3
/h
Type m
3
/h cfm VAC Hz Bel(A) / Watts rpm
-1
°C Hours Hours
RG 125-19/56 86 51 230 50 5.8 20.0 2 550 -30...+70 37 500 / 20 000 ¿
RG 125-19/06 94 55 115 60 6.0 19.0 2 750 -30...+80 40 000 / 15 000 ¡
Subject to change
– Material: Scroll housing: GRP
1)
(PBT)
Impeller: GRP
1)
(PA)
Housing base: Sheet steel
– Direction of air flow: Centrifugal: discharge through
window in housing
– Direction of rotation: Clockwise,
looking towards rotor
– Connection: To 2 single wires AWG 22.
– Highlights: Backward-curved impeller
– Weight: 850 g
1) Fiberglass-reinforced plastic
Nominal voltage
Air flow
Air flow
Frequency
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L
10
at 40 °C
at T
max
Curve
Sound power level
Tin-plated
Finger guards
from p. 242
AC centrifugal fans
180 x 40 mm
Series RG 125
Nominal data