Thermal automotive Mini-CBE 1626-...
www.e-t-a.de
1646
1
1
Description
Typical applications
Current ratings, typical voltage drop values and colour coding
Technical data
Single pole, thermal miniaturised circuit breaker designed for automotive
applications. Fits into fuse blocks designed to ISO 8820-3, Type F.
Automatic reset (for DC 12 V only) and open circuit (modified reset to
SAE) version optional. Open circuit version ensures contacts staying
open as long as power is on. The circuit breaker will reset after the
load is removed. Particularly suitable for installation in inaccessible
locations.
Current ratings correspond to those of blade fuses. Clear colour
coding of the ratings: blade fuse and circuit breaker of the same colour
have the same rating.
Breakers rated 7.5 A through 30 A have a fast characteristic curve and
only hold 70 % of their rated current continuously.
US patent number: US 8,576,042,B2
Protection of electrical systems of passenger cars, trucks, buses,
watercraft, extra low voltage wiring systems.
1626-1/-2 1626-3 1626-3H
Voltage rating 1626-1/-2: DC 12 V
1626-3/-3H: DC 12 V, DC 24 V
Max. voltage rating 1626-1/-2: DC 14.5 V
1626-3/-3H: DC 29.0 V
Current ratings 5...30 A
5 A: medium characteristic curve
7.5...30 A: fast characteristic curve
Service short-circuit
breaking capacity 300 operations at 2 x I
N
Ambient temperature -40...+85 °C (-40…+185 °F)
(for higher temperatures please enquire)
Reset period for 1626-1
(at 23 °C) ≤ 15 s
Reset period for 1626-2
(at 23 °C) after 5 sec at
rated voltage < 35 s
Degree of protection
(IEC 60529) operating area IP40 (-3)
operating area IP50 (-1, -2)
terminal area IP00
Ultimate short-circuit
breaking capacity ≥ 3 break operations at 150 A, or
≥ 1 break operation at 2,000 A
Vibration 10 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
SAE-J553, Step No. 14, § 4.2.7.1.5
Shock 50 g (11 ms)
to IEC 60068-2-27, test Ea
SAE-J553, Step No. 14, § 4.2.7.1.6
Corrosion 96 hrs in 5 % salt mist,
to IEC 60068-2-11, test Ka
SAE-J553, Step No. 14, § 4.2.7.1.3
Humidity 240 hrs in 95 % RH,
to IEC 60068-2-78, test Cab
SAE-J553, Step No. 14, § 4.2.7.1.2
Mass approx. 3 g
Caution:
It is good practice to switch off the vehicle’s ignition system before
manually releasing or re-setting the circuit breaker. Free travel of the
reset button must be ensured! Please ensure to push in the actuator
smoothly and completely.
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved. Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
Ordering information
Type No.
1626 single pole thermal Mini-CBE with standard characteristic curve
Version, according to SAE J553
1 type 1, DC 12 V automatic reset
2 type 2, DC 12 V modified reset
3 type 3, DC 24 V with reset button
3H type 3*, DC 24 V with reset button and manual release facility
Current ratings
5 7.5 10 15 20 25 30 A
1626 - 1 - 10 A ordering example
Current rating (A) Voltage drop (mV) Housing cap colour
5 < 150 light brown
7.5 < 150 brown
10 < 150 red
15 < 150 blue
20 < 150 yellow
25 < 150 white
30 < 150 light green