6J4-2

J Series
J Series
Power Entry Module with Voltage Selection and Fusing
172
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
UL Recognized
CSA Certified
Ordering Information
6 H J 4 -4
Available Voltage Selections
1 - Four (non–filtered versions)
2 – Two
4 or blank – Four (filtered versions)
Filtered Indicator
1 – Non–filtered
4 – Filtered
J
Series
Filter Type
H – Medical
V – Non-filtered
Blank – general purpose
C
urrent Rating
6A
Front View, all models
Maximum leakage current each Line to Ground:
6HJ4 or
6J4 Models
non–filtered
@250 VAC 50 Hz: 500 A 5 A
Hipot rating (one minute):
Line to Ground: 1550 VAC
Line to Line: 1450 VDC
Operating Voltage:
suffix - 1 or - 4 models: 100, 120, 220 or 240VAC
suffix - 2 models: 115 or 230 VAC
Operating Frequency: 50/60 Hz
Rated Current: 6A
Required Fuse: .25 x 1.25
(not included)
Specifications
Available Part Numbers
6J4
• Power entry module with North American style
3AG fuse holder
• 2 or 4 voltage selection
• Compact snap-in design
• Two element circuit provides basic
EMI attenuation
• Available with minimal leakage current suitable
for medical applications (HJ models)
• Also available without filter (VJ models)
Non–filtered models
6VJ1 6VJ1-2
General Purpose Filters
6J4 6J4-2
Medical Filters
6HJ4-4 6HJ4-2
6HJ4
J Series
Power Entry Module with Voltage Selection and Fusing (continued)
Power Inlet Filters & Power Entry Modules
3
173
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Voltage Selection
Open cover door and slide fuse-pull lever to left.
Select operating voltage by orienting voltage selec-
tion card with the desired voltage on top left side.
Push card firmly into module slot. Slide fuse-pull lever
to right into normal position and re-insert fuse into
holders.
Use caution in selecting correct fuse value.
Electrical Schematics
6VJ1 & 6VJ1-2
Hot
S
R
H
Neutral
P
N
M
Note 1
Pilot
light
Transformer
primary
100V
120V
220V
240V
A
A
B
B
J
C
D D
K
E
L
F
Power On/Off
Off
On
Ground
Note 2
Note 2
Note 3
100V
20V
120V
6J4 & 6J4-2
Hot
Neutral
Note 1
Pilot
light
Transformer
primary
100V
120V
100V
20V
120V
220V
240V
A
A
B
B
C
C
DD
E
E
F
J
H
F
Power On-O
O
On
Ground
Note 3
6HJ4-4 & 6J4-2
Hot
Neutral
Note 1
Pilot
light
Transformer
primary
100V
120V
100V
20V
120V
220V
240V
A
A
B
B
C
C
DD
E
E
F
J
H
F
Power On-O
O
On
Ground
Note 3
 
 
 
GA400
:NEMA 5-15P to IEC 60320-1 C-13 line cord
Accessories
JA302
: 2 Voltage Select Card
Comes standard with 6VJ1-2, 6J4-2 and
6HJ4-2
JA304
: 4 Voltage Select Card
Comes standard with 6VJ1, 6J4 and 6HJ4-4
J
A403
: Mounting clips for .105 - .125” panels
J
A500
: Voltage Selector Card Extractor Tool
A B C
VA Fuse Fuse
Part No. max. 100/120 (115) 220/240 (230)
JA410 25 250 mA 125 mA
JA411 50 500 mA 250 mA
JA412 100 1A 500 mA
JA413 200 2A 1A
JA414 250 2.5A 1.25A
JA415 300 3A 1.5A
JA416 400 4 A 2A
JA417 500 5A 2.5A
JA418 600 6A 3A
JA419 Assortment
JA410-JA418: 40 labels of one part number
JA419: 5 each of JA410 - JA418 (45 labels)
JA410-419:
Equipment Rating Labels
Self-adhesive, available in multiples of 40
Specify part number
C
B
A
2.330
.210
Line V. + 5 - 10%
48-440 - 50 VA Max.
Fuse
100/120V (115V) 220/240V
(230V)
500mA 250mA
J Series
Power Entry Module with Voltage Selection and Fusing (continued)
174
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Case Styles
Non-filtered Models
A
C
B
D

 
 
Filtered Models
A
C
B
D

 
 
Recommended Panel Cutouts
Door Open Position
Bezel
Clearance
2.60*
66.0
2.68
68.1
3.00
76.2
1.063*
27.0
1.17
29.7
*± .003 [.076]



Part No.
ABCD
   
6VJ1, 6VJ1-2
   
   
6J4, 6J4-2,
6HJ4-4, 6HJ4-2
   
   
Case Dimensions
Performance Data
Typical Insertion Loss
6J4 6HJ4
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Measured in closed 50 Ohm system
  
      
      
     

6J4-2

Mfr. #:
Manufacturer:
TE Connectivity / Corcom
Description:
AC Power Entry Modules 6A IEC-.045CONN BLOK FILTRD/SNAP IN MOUNT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet