MINI MCR-SL-CVS-24-5-10-NC
105264_en_01 PHOENIX CONTACT 4
4 Technical data
Input
Voltage input signal 9.6 V DC ... 30 V DC
Output
Max. voltage output signal 10 V DC
7.5 V DC
5 V DC
2.5 V DC
Configurable/programmable Yes, preconfigured
Short-circuit current approx. 32 mA
Ripple < 20 mV
PP
Supply
Nominal supply voltage 24 V DC
Supply voltage range 9.6 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order
No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a
35 mm DIN rail according to EN60715))
Max. current consumption < 25 mA (10V output with 30mA load at 24V DC IN)
< 65 mA (10V output with 30mA load at 9.6V DC IN)
< 50 mA (10V voltage output with 30 mA load at 12V DC IN)
< 20 mA (10V voltage output with 30 mA load at 30V DC IN)
Power consumption < 600 mW (at 24 V IN)
< 624 mW (at 9.6 V IN)
< 564 mW (At 12 V IN)
< 540 mW (At 30 V IN)
General data
Maximum transmission error 0.1 % (of final value)
0.5 % (Without adjustment)
Temperature coefficient, typical < 0.002 %/K
Maximum temperature coefficient < 0.01 %/K
Electrical isolation Basic insulation according to EN 61010
Surge voltage category II
Mounting position Any
Degree of protection IP20
Pollution degree 2
Rated insulation voltage 50 V AC/DC
Dimensions W / H / D 6.2 mm / 93.1 mm / 102.5 mm
Type of housing PBT green
Connection data Screw connection Spring-cage conn.
Conductor cross section, solid 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm²
Conductor cross section, stranded 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm²
Stripping length 12 mm 8 mm
Ambient conditions
Ambient temperature (operation) -20 °C ... 65 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
MINI MCR-SL-CVS-24-5-10-NC
105264_en_01 PHOENIX CONTACT 5
Conformance with EMC Directive 2004/108/EC
Noise immunity according to EN 61000-6-2
When being exposed to interference, there may be minimal deviations.
Noise emission according to EN 61000-6-4
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada 508 listed
UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T5 applied for
MINI MCR-SL-CVS-24-5-10-NC
105264_en_01 PHOENIX CONTACT 6
5 Safety regulations and installation notes
5.1 Installation notes
The category 3 device is suitable for installation in the
zone 2 potentially explosive area. It fulfills the require-
ments of EN60079-0:2009 and EN60079-15:2010.
Installation, operation, and maintenance may only be
carried out by qualified electricians. Follow the installa-
tion instructions described. When installing and operat-
ing the device, the applicable regulations and safety
directives (including national safety directives), as well
as general technical regulations, must be observed.
The technical data is provided in this package slip and
on the certificates (conformity assessment, additional
approvals where applicable).
It is not permissible to open or modify the device. Do not
repair the device yourself but replace it with an equiva-
lent device. Repairs may only be carried out by the man-
ufacturer. The manufacturer is not liable for damage
resulting from violation.
The IP20 degree of protection (IEC60529/EN60529) of
the device is intended for use in a clean and dry environ-
ment. Do not subject the device to any load that ex-
ceeds the described limits.
The device is not designed for use in atmospheres with
a danger of dust explosions.
5.2 Installation in the Ex area (zone 2)
Observe the specified conditions for use in potentially
explosive areas.
The device must be installed in a housing (control or dis-
tributor box) which meets the requirements of EN
60079-15 and provides at least IP54 (EN 60529) degree
of protection.
During installation and when connecting the supply and
signal circuits, observe the requirements of EN 60079-
14. Devices may only be connected to circuits in zone 2
if they are suitable for operation in Ex zone 2 and for the
prevailing conditions at the place of use.
In potentially explosive areas, terminals may only be
snapped onto or off the DIN rail connector and wires
may only be connected or disconnected when the pow-
er is switched off.
The device must be stopped and immediately removed
from the Ex area if it is damaged, has been subjected to
an impermissible load, has been stored incorrectly, or if
it malfunctions.
You can download the latest documents for these de-
vices from www.phoenixcontact.net/products.

2902823

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules MINI MCR-SL-CVS 24-5-10-SP-NC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet