REV. 0
ADG604
–5–
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the ADG604 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
ABSOLUTE MAXIMUM RATINGS
1
(T
A
= 25°C unless otherwise noted)
V
DD
to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 V
V
DD
to GND . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6.5 V
V
SS
to GND . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –6.5 V
Analog Inputs
2
. . . . . . . . . . . . . . . . V
SS
–0.3 V to V
DD
+ 0.3 V
Digital Inputs
2
. . . . . . . . . . . . . . . . . –0.3 V to V
DD
+ 0.3 V or
. . . . . . . . . . . . . . . . . . . . . . 30 mA, Whichever Occurs First
Peak Current, S or D . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
(Pulsed at 1 ms, 10% Duty Cycle Max)
Continuous Current, S or D . . . . . . . . . . . . . . . . . . . . 10 mA
Operating Temperature Range
Automotive (Y Version) . . . . . . . . . . . . . . –40°C to +125°C
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
ORDERING GUIDE
Model Option Temperature Range Package Description Package
ADG604YRU –40°C to +125°C Thin Shrink Small Outline (TSSOP) RU-14
PIN CONFIGURATION
A0
EN
V
SS
S1
S2
D
NC
1
A1
GND
V
DD
S3
S4
NC
NC
ADG604
2
3
4
5
6
7
14
13
12
11
10
9
8
TOP VIEW
(Not To Scale)
NC = NO CONNECT
Table I. Truth Table
A1 A0 EN ON Switch
X X 0 None
0011
0112
1013
1114
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
TSSOP Package
JA
Thermal Impedance . . . . . . . . . . . . . . . . . . . . 150°C/W
JC
Thermal Impedance . . . . . . . . . . . . . . . . . . . . . 27°C/W
Lead Temperature, Soldering (10 seconds) . . . . . . . . . 300°C
IR Reflow, Peak Temperature . . . . . . . . . . . . . . . . . 220°C
NOTES
1
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability. Only one absolute
maximum rating may be applied at any one time.
2
Overvoltages at EN, A0, A1, S, or D will be clamped by internal diodes. Current
should be limited to the maximum ratings given.