cui.com
CUI Inc │ SERIES: VHB350 │ DESCRIPTION: DC-DC CONVERTER date 03/14/2013 │ page 2 of 4
INPUT
parameter conditions/description min typ max units
operating input voltage
18
36
24
48
36
75
Vdc
Vdc
surge voltage
1
24 V input
48 V input
50 Vdc
under voltage lockout
power up
24 V input
48 V input
16
34
17
35
18
36
Vdc
Vdc
power down
24 V input
48 V input
15
32
16
33
17
35
Vdc
Vdc
over voltage protection
turn on
24 V input
48 V input
38
77
Vdc
Vdc
turn off
24 V input
48 V input
40
80
Vdc
Vdc
positive logic remote on/off see note 2
lter PI type
Notes: 1. 100 ms max
2. logic compatibility, open collector ref to -input
Module ON, >3.5 to 75 Vdc or open circuit
Module OFF, <1.2 Vdc
OUTPUT
parameter conditions/description min typ max units
line regulation measured from high line to low line ±0.2 %
load regulation measured from full load to zero load ±0.2 %
voltage accuracy ±1.5 %
transient response 25% step load change 500 µs
adjustability
3
±10 %
switching frequency
3.3 and 5 V models
all other models
300
330
kHz
kHz
temperature coefcient ±0.03 %/°C
Notes: 3. trim-up: connect a resistor between the trim pin and +Sense
trim-down: connect a resistor between the trim pin and -Sense
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection %Vo 115 140 %
short circuit protection continuous
current limit 105 140 %
thermal shutdown case temp. 110 °C
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output
input to case
output to case
1,500
1,500
1,500
Vdc
Vdc
Vdc
isolation resistance 10
MΩ
isolation capacitance 1,000
pF
safety approvals UL60950-1, EN60950-1
RoHS compliant yes
For more information, please visit the product page.