BU2285FV,BU2363FV
Technical Note
3/16
www.rohm.com
2009.04 - Rev.
© 2009 ROHM Co., Ltd. All rights reserved.
◎BU2363FV(VDD=3.3V, Ta=25℃, Crystal frequency 36.8640MHz, unless otherwise specified.)
Parameter Symbol
Limits
Unit Conditions
Min. Typ. Max.
Output L voltage VOL - - 0.4 V IOL=4.0mA
Output H voltage VOH 2.4 - - V IOH=-4.0mA
Consumption current IDD - 30 50 mA At no load
CLK54M CLK54M - 54.0000 - MHz XTAL×375 / 64 / 4
CLK27M CLK27M - 27.0000 - MHz XTAL×375 / 64 / 8
CLK33M CLK33M - 33.8688 - MHz XTAL×147 / 40 / 4
CLK16M CLK16M - 16.9344 - MHz XTAL×147 / 40 / 8
CLK768FS1
CLK768_H - 36.8640 - MHz
At FSEL=OPEN,
XTAL output
CLK768_L - 33.8688 - MHz
At FSEL=L,
XTAL×147 / 40 / 4
CLK384FS2
CLK384_H - 18.4320 - MHz
At FSEL=OPEN,
XTAL / 2 output
CLK384_L - 16.9344 - MHz
At FSEL=L,
XTAL×147 / 40 / 8
Duty Duty 45 50 55 % Measured at a voltage of 1/2VDD
Period-Jitter 1σ P-J 1σ - 50 - psec *1
Period-Jitter MIN-MAX
P-J
MIN-MAX
- 300 - psec *2
Rise Time Tr - 2.5 - nsec
Period of transition time required for the clock
output to reach 80% from 20% of VDD
Fall Time Tf - 2.5 - nsec
Period of transition time required for the clock
output to reach 20% from 80% of VDD
Output Lock-Time Tlock - - 1 msec *3
C/N 54M C/N 54M -65 -80 - dB *4 (At a maximum load)
C/N 33M C/N 33M -50 -60 - dB *4 (At a maximum load)
Note) The output frequency is determined by the arithmetic (frequency division) expression of a frequency input to XTALIN.
If the input frequency is set to 36.8640MHz, the output frequency will be as listed above.
Common to BU2285FV and BU2363FV:
*1 Period-Jitter 1σ
This parameter represents standard deviation (1 σ) on cycle distribution data at the time when the output clock cycles
are sampled 1000 times consecutively with the TDS7104 Digital Phosphor Oscilloscope of Tektronix Japan, Ltd.
*2 Period-Jitter MIN-MAX
This parameter represents a maximum distribution width on cycle distribution data at the time when the output clock
cycles are sampled 1000 times consecutively with the TDS7104 Digital Phosphor Oscilloscope of Tektronix Japan, Ltd.
*3 Output Lock-Time
The Lock-Time represents elapsed time after power supply turns ON to reach a 3.0V voltage, after the system is
switched from Power-Down state to normal operation state, or after the output frequency is switched, until it is stabilized
at a specified frequency, respectively.
BU2363FV
*4 Make measurements with settings of SPAN to 100kHz, RBW to 1kHz, and VBW to 100Hz taking the middle point
between (54.0000MHz20kHz) and (33.8688MHz20kHz) as a measurement point.