Si7022-A10
4 Rev. 1.1
1. Electrical Specifications
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
Parameter
Symbol Test Condition Min Typ Max Unit
Power Supply V
DD 1.9 3.6 V
Operating Temperature T
A –40 +125 °C
Table 2. General Specifications
1.9 < VDD < 3.6 V; TA = –40 to 125 °C unless otherwise noted.
Parameter Symbol Test Condition Min Typ Max Unit
Input Voltage High V
IH
SELECT pin 0.7xVDD ——V
Input Voltage Low V
IL SELECT pin 0.3xVDD V
Input Voltage Range V
IN SELECT pin with respect to GND 0.0 VDD V
Input Leakage I
IL SELECT pin 1 μA
Output Voltage High V
OH PWM1, PWM2 pins, IOH = –10 μA VDD – 0.1 V
PWM1, PWM2 pins pin,
IOH = –0.5 mA, VDD = 2.0 V
VDD – 0.2
PWM1, PWM2 pins,
IOH = –1.7 mA, VDD = 3.0 V
VDD – 0.4
Output Voltage Low V
OL PWM1, PWM2 pins; IOL = 2.5 mA;
V
DD =3.3V
——0.6V
PWM1, PWM2 pins; I
OL = 1.2 mA;
V
DD =1.9V
——0.4V
Sample Rate
RH and Temperature 2 Hz
Current
Consumption
I
DD Average Current 150 300 μA
Powerup Time t
PU
From VDD 1.9 V to PWM output
enabled, 25 °C
—4855
ms
From V
DD 1.9 V to PWM output
enabled, full temperature range
——110
Si7022-A10
Rev. 1.1 5
Figure 1. PWM Interface Timing Diagram
Table 3. PWM Interface Specifications
1.9 V
DD
3.6 V; T
A
= –40 to +125 °C unless otherwise noted.
Parameter Symbol Test Condition Min Typ Max Unit
PWM Frequency F
PWM
1.00 1.22 1.40 kHz
PWM Duty Cycle DC
PWM
t
H
/ t
PWM
0 100 %
SELECT Setup Time t
SS
From SELECT transition to
PWM valid
—500ms
t
PWM
t
H
t
SS
RH Data Temperature Data
Si7022-A10
6 Rev. 1.1
Figure 2. RH Accuracy at 30 °C
Table 4. Humidity Sensor
1.9 V
DD
3.6 V; T
A
= 30 °C
Parameter Symbol Test Condition Min Typ Max Unit
Operating Range
1
Non-condensing 0 100 %RH
Accuracy
2, 3
0 – 80% RH ±3 ±4 %RH
80 – 100% RH See Figure 2
Repeatability/Noise 0.025 %RH RMS
Resolution 11 Bits
Response Time
4
τ
63%
1 m/s airflow, with or without cover 6 S
Drift vs. Temperature 0.05 %RH/°C
Hysteresis ±1 %RH
Long Term Stability
3
—<0.25 %RH/yr
Notes:
1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged
operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.
2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See section “4.1. Relative Humidity Sensor Accuracy” for more details.
3. Drift due to aging effects at typical room conditions of 30 °C and 30% to 50% RH. May be impacted by dust, vaporized
solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See section “4.7. Long
Term Drift/Aging” .
4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.

SI7022-A10-IM1

Mfr. #:
Manufacturer:
Silicon Labs
Description:
Board Mount Humidity Sensors Dig RH +/-4% max & temp sens ind grd
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet