MAX3992UTG+T

MAX3992
10Gbps Clock and Data Recovery
with Equalizer
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(See Table 1 for operating conditions. Typical values at V
CC
= +3.3V, T
A
= +25°C, unless otherwise noted.)
Note 1: Measured with 100mV
P-P
differential amplitude.
Note 2: Guaranteed by design and characterization.
Note 3: Measured from the time that the FCTL1 input goes high with FCTL2 = 0, to the time when the supply current drops to less
than 40% of the nominal value.
Note 4: Measured with PRBS = 2
31
- 1.
Note 5: Larger C
FILT
can be used to reduce jitter peaking at 120kHz. A larger C
FILT
will increase acquisition time. C
FILT
should
not exceed 200nF.
Note 6: Measurement limited by test equipment.
Note 7: Jitter tolerance is for BER 10
-12
, measured with additional 0.1VI deterministic jitter through 15 inches of FR4. (See Typical
Operating Characteristics 1.)
Note 8: Measured with 50kHz to 80MHz SONET filter.
Note 9: Applies on power-up or after standby.
Note 10: Over process, temperature and supply.
Note 11: Hysteresis is defined as 20Log(V
LOS-DEASSERT
/V
LOS-ASSERT
).
Table 2. Serial Data Rate and Reference Clock Frequency
APPLICATION
DATA RATE (Rb)
(Gbps)
/16 REFERENCE CLOCK
FREQUENCY (MHz)
/64 REFERENCE CLOCK
FREQUENCY (MHz)
OC-192 SONET – SDH64
9.95328 622.08
155.52
OC-192 SONET over FEC
10.664 666.5
166.625
ITU G.709
10.709 669.3125
167.328125
10Gbps Ethernet, IEEE 802.3ae
10.3125 644.53125
161.1328125
10Gbps Ethernet over ITU G.709
11.09573 693.483125
173.3707813
10Gbps Fibre Channel
10.51875 657.421875
164.355469
Table 1. Operating Conditions (Unless otherwise noted, FCTL1 = FCTL2 = 0.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
UNITS
Supply Voltage V
CC
3.0 3.6 V
Ambient Temperature T
A
0
+85
°C
Input Data Rate Rb (See Table 2)
Gbps
Differential Input Voltage to
Transmission Line
V
D
0 to 12 inches FR-4
400 1000
mV
P-P
Output Load Resistance RL RL is AC-coupled 50
REFCLK± Differential Input Voltage
Swing
300 1600
mV
P-P
REFCLK Duty Cycle 30 70 %
Rb / 16
REFCLK Frequency
f
REFCLK
Rb / 64
GHz
REFCLK Accuracy Relative to Rb / 16 or Rb / 64
-100 +100
ppm
F
REFCLK
= Rb / 64
1200
REFCLK Rise/Fall Times (20% to
80%)
f
REFCLK
= Rb / 16
300
ps
REFCLK Random Jitter Noise bandwidth < 100MHz 10
ps
RMS
Note: The part should be in standby mode when data rates are being switched.
MAX3992
10Gbps Clock and Data Recovery
with Equalizer
_______________________________________________________________________________________ 5
Figure 1. TX LOL Assert and PLL Acquisition Time
LOL
ACQUISITION
TIME
LOL
ASSERT TIME
*ASSERT AND ACQUISITION TIME ARE DEFINED
WITH A VALID REFERENCE CLOCK APPLIED.
651ppm
500ppm
f/f
REFCLK
Figure 2. LOS Assert/Deassert Time
LOS
LOS DEASSERT TIME
DATA INPUT
POWER
LOS ASSERT TIME
LOL
ACQUISITION TIME
MAX3992
10Gbps Clock and Data Recovery
with Equalizer
6 _______________________________________________________________________________________
Typical Operating Characteristics
(V
CC
= 3.3V, T
A
= +25°C, unless otherwise noted.)
NORMALIZED BIT TIME (UI)
MAX3992 INPUT
(15in FR-4)
MAX3992 toc01
DIFFERENTIAL SIGNAL AMPLITUDE (mV)
-500
-50
50
500
0 0.35
0.65
1
RECOVERED REFERENCE SIGNAL
PRBS 2
31
-1 15in FR-4
MAX3992 toc02
DIFFERENTIAL SIGNAL AMPLITUDE
(100mV/div)
NORMALIZED BIT TIME (UI)
0
1
0
6
4
2
8
10
12
14
16
02010 30 40 50
JITTER GENERATION vs. POWER-SUPPLY
WHITE NOISE AMPLITUDE (BW < 100kHz)
MAX3992 toc03
NOISE AMPLITUDE (mV
RMS
)
JITTER GENERATION (mUI
RMS
)
PRBS 2
31
-1
POWER-SUPPLY INDUCED OUTPUT
JITTER vs. RIPPLE FREQUENCY
MAX3992 toc04
FREQUENCY (Hz)
JITTER GENERATION (ps
P-P/
mV
P-P
)
1M100k10k
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0
1k 10M
SINUSOIDAL JITTER TOLERANCE
12in FR-4 2
31
-1 PRBS DATA
MAX3992 toc05
FREQUENCY (Hz)
JITTER TOLERANCE (U|
P-P
)
10M1M100k
1
10
100
0.01
1k 10k 100M
TOLERANCE EXCEEDS
MODULATION
CAPABILITIES OF TEST
EQUIPMENT
XFI TELECOM
MASK
0.1
JITTER TRANSFER
MAX3992 toc06
FREQUENCY (Hz)
JITTER TRANSFER (dB)
10M1M10k 100k
-18
-15
-12
-9
-6
-3
0
3
-21
1k 100M
80
110
100
90
120
130
140
-10 30200 10 405060708090
MAX3992
SUPPLY CURRENT vs. TEMPERATURE
MAX3992 toc07
TEMPERATURE (°C)
SUPPLY CURRENT (mA)
DIFFERENTIAL S11
SDD11
MAX3992 toc08
FREQUENCY (Hz)
SDD11 (dB)
10G1G100M
-35
-30
-25
-20
-15
-10
-5
0
5
10
-40
10M 100G
XFI MASK

MAX3992UTG+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Timers & Support Products
Lifecycle:
New from this manufacturer.