XR17V354/SP339-E4-EB

4
XR17V358/354 EVALUATION BOARD USER’S MANUAL REV. 1.0.1
2.5 Jumper/Switch Settings for RS-232 or RS-485 for Master Device
The following table (Table 5) shows the setting for selecting between the RS-232 or RS-485 modes for the
master device. The Half-duplex RS-485 mode can be enabled by either setting the FCTR bit-5 to 1 or
connecting the EN485# pin to GND.
TABLE 5: SETTINGS FOR RS-232 OR RS-485 MODE FOR MASTER DEVICE
JUMPERS/
S
WITCH
FUNCTIONS COMMENTS
J13 3.3V Supply voltage pin for transceivers Not installed. Trace between 1&2.
J41 Enable Auto RS-485 Half-Duplex Direction Control
upon power-up
Jumper between 1&2 enables this feature for all 8
channels. This feature can be disabled in the software
after power-up.
J54 Enable IR mode upon power-up Jumper between 1&2 enables this feature for all 8
channels. This feature can be disabled in the software
after power-up.
SW5 Indicate whether slave device is presented or not.
OFF ON
1
2
3
4
5
6
7
8
SW5
Default for “0A-EVB
Slave is not present (default for "0A-EVB" board).
Position 1 = OFF
Slave is present (default for "Ex-EVB" board).
Position 1 = ON
Position 2, Position 3, Position 4, Position 5, Position
6, Position 7, and Position 8 are for internal use only.
They should be set as OFF status (default).
5
REV. 1.0.1 XR17V358/354 EVALUATION BOARD USERS MANUAL
SW1 Selects between RS-232 and half-duplex RS-485
mode for UART channels 0 and 1
OFF ON
1
2
3
4
5
6
7
8
SW1
RS-232 Mode (Default)
UART channel 0 RS-232 Mode (default)
Position 1 = OFF
Position 2 = OFF
Position 3 = ON
Position 4 = ON
UART channel 0 half-duplex RS-485 Mode
Position 1 = OFF
Position 2 = ON
Position 3 = OFF
Position 4 = ON
UART channel 1 RS-232 Mode (default)
Position 5 = ON
Position 6 = ON
Position 7 = OFF
Position 8 = OFF
UART channel 1 half-duplex RS-485 Mode
Position 5 = ON
Position 6 = OFF
Position 7 = ON
Position 8 = OFF
SW4 Selects between RS-232 and half-duplex RS-485
mode for UART channels 2 and 3
OFF ON
1
2
3
4
5
6
7
8
SW4
RS-232 Mode (Default)
UART channel 2 RS-232 Mode (default)
Position 1 = OFF
Position 2 = OFF
Position 3 = ON
Position 4 = ON
UART channel 2 half-duplex RS-485 Mode
Position 1 = OFF
Position 2 = ON
Position 3 = OFF
Position 4 = ON
UART channel 3 RS-232 Mode (default)
Position 5 = ON
Position 6 = ON
Position 7 = OFF
Position 8 = OFF
UART channel 3 half-duplex RS-485 Mode
Position 5 = ON
Position 6 = OFF
Position 7 = ON
Position 8 = OFF
TABLE 5: SETTINGS FOR RS-232 OR RS-485 MODE FOR MASTER DEVICE
JUMPERS/
S
WITCH
FUNCTIONS COMMENTS
6
XR17V358/354 EVALUATION BOARD USER’S MANUAL REV. 1.0.1
SW6 Selects between RS-232 and half-duplex RS-485
mode for UART channels 4 and 5
OFF ON
1
2
3
4
5
6
7
8
SW6
RS-232 Mode (Default)
UART channel 4 RS-232 Mode (default)
Position 1 = OFF
Position 2 = OFF
Position 3 = ON
Position 4 = ON
UART channel 4 half-duplex RS-485 Mode
Position 1 = OFF
Position 2 = ON
Position 3 = OFF
Position 4 = ON
UART channel 5 RS-232 Mode (default)
Position 5 = ON
Position 6 = ON
Position 7 = OFF
Position 8 = OFF
UART channel 5 half-duplex RS-485 Mode
Position 5 = ON
Position 6 = OFF
Position 7 = ON
Position 8 = OFF
SW3 Selects between RS-232 and half-duplex RS-485
mode for UART channels 6 and 7
OFF ON
1
2
3
4
5
6
7
8
SW3
RS-232 Mode (Default)
UART channel 6 RS-232 Mode (default)
Position 1 = OFF
Position 2 = OFF
Position 3 = ON
Position 4 = ON
UART channel 6 half-duplex RS-485 Mode
Position 1 = OFF
Position 2 = ON
Position 3 = OFF
Position 4 = ON
UART channel 7 RS-232 Mode (default)
Position 5 = ON
Position 6 = ON
Position 7 = OFF
Position 8 = OFF
UART channel 7 half-duplex RS-485 Mode
Position 5 = ON
Position 6 = OFF
Position 7 = ON
Position 8 = OFF
TABLE 5: SETTINGS FOR RS-232 OR RS-485 MODE FOR MASTER DEVICE
JUMPERS/
S
WITCH
FUNCTIONS COMMENTS

XR17V354/SP339-E4-EB

Mfr. #:
Manufacturer:
MaxLinear
Description:
Interface Development Tools Eval Board for XR17V354IB-E4